Andromeda MAX VAP mod.2009 v1.1
pag. 4
gennaio 2009
ESC
ESC
Key to exit the current function.
UP
DOWN
°C
UP
DOWN
Key to scroll up or down.
RESET
RESET
Key to reset warnings such as: filter cleaning, probe
cleaning, cover changing and zeroing of partial hours.
7.
MEANING OF ICONS
Indicates that the water inside the boiler is being heated in order to obtain
the correct operating pressure. When this icon turns off it means that the
boiler has reached the optimum pressure.
Indicates that the pump is pumping water into the boiler.
Indicates that the ironing board is being heated in order to reach the set
temperature. When this icon turns off it means that the ironing board has
reached the right temperature.
Indicates that the pump is blocked due to the fact that it has worked
without water for a long time. Check that water comes out of the pipe
connected to the water supply. Turn off the main switch, wait for 5 seconds
and turn the machine on again. If the problem reoccurs, contact Authorized
Service Centre.
Indicates that the electronic card is in SET mode and data may be set (see
SET & RESET)
Indicates a malfunctioning of the temperature probe of the ironing board.
WARNING: A safety device will block the heating of the ironing board.
Contact Authorized Service Centre.
Indicates that the maximum number of hours set for the replacement of the
cover has been exceeded. Change the cover and reset the warning. (see
SET & RESET)
Indicates that the maximum number of hours set for the cleaning of the
water filter has been exceeded. Clean the water filter and reset the
warning. (see SET & RESET)
Indicates that the maximum number of hours set for the general
maintenance of the machine has been exceeded. Contact the manufacturer
or Authorized Service Centre for this intervention.