BatteryMINDer
®
Models 36271 & 48021
Rev. D-120913
Page 14
P/N VDC36271/48021-MNL
LED INDICATOR FUNCTIONS
Battery Condition Table
Battery Condition
Battery Voltage (Vb)
Battery Condition Indication
36271
48021
BEFORE
full charge
<33
<44
>33
>44
Stop/Restart
during charging
mode
REBOOT
to restart*
AFTER
full charge
Low Voltage
Normal Voltage
*To
REBOOT
: Disconnect A.C. wall power, disconnect D.C. Battery power and wait 10 seconds
LED Status Table
LED Status
(Power/Error and Charging/Maintaing LEDs)
POWER
ERROR
CHARGE - FLOAT
A.C. power disconnected, battery connected
correctly
OFF
OFF
At SoftStart mode, Bulk charge mode or Absorption
mode
ON
ON
Float charge mode
ON
FLASHING
A.C. power connected Reversed Battery Polarity
ON
OFF
A.C. power connected, charger output clip shorted
ON
OFF
A.C. power connected, battery voltage <9V (
36271
)
or <12V (
48021
)
ON
OFF
Timed-out when in SoftStart or Bulk mode
FLASHING
OFF
Timed-out when in Absorption mode & Forced to
Float mode
FLASHING
FLASHING
Battery Fault / Battery Weak
FLASHING
OFF