background image

BatteryMINDer

® 

   

Models 128CEC1 & 244CEC1

Rev. A2-010516 

 

 

 

Page 7 

P/N VDC

128

/

244-CEC1

-QSS

beyond the point of being properly recharged or reconditioned/desulfated. 

Dispose of the battery.

4. 

If each cell floats three (3) or more balls (or 1250 on gauge-type), your 

battery can be desulfated/reconditioned.

5. 

Always rinse the tester with fresh water after every use.  Failure to do so 

will cause false readings.

Testing a Sealed, AGM or GEL Lead Acid Battery

These batteries have no filler caps or manifold-type covers.  Because you 

cannot gain access to the interior of your battery you cannot test it with a 

hydrometer.  

USE A DIGITAL VOLTMETER ONLY:

1. 

Recharge the battery with the BatteryMINDer to ensure it is as completely 

charged as possible, before you determine its condition. Allow battery to 

“rest” overnight for a minimum of 12 hours before testing with a digital 

voltmeter only.  Failure to test a “rested” battery will cause false readings.  

Be certain to read and understand all safety related instructions (pages 2 

to 7) before proceeding further.

2. 

Measure battery’s voltage, without any load attached.  If the voltage is less 

than 

12.4 volts

 

/

 

24.8 volts

 (Typically 50% of charge) the battery may be 

too heavily sulfated to be fully recoverable.  If voltage is 

12.4V 

24.8V

 

or 

higher full recovery can be expected, given sufficient time (average 1-2 

weeks for batteries that are heavily sulfated).

3. 

Connect the BatteryMINDer to the battery.  Charge battery to its maximum 

level.  Allow battery to rest for a minimum of 8 hours before retesting.  If 

improvement is seen, continue until battery voltage reaches full capacity 

level or no further increase is seen.  Refer to 

Open Circuit No Load 

Voltage

 table.

OCV=Open Circuit No Load Voltage

OCV - “Rested” Voltage

Full Capacity 

Percentage

12V

24V

12.9 - 13.1

25.8 - 26.2

100%

12.6 - 12.9

25.2 - 25.8

75%

12.4 - 12.6

24.8 - 25.2

50%

12.2 - 12.4

24.4 - 24.8

25%

12.0 - 12.2

24.0 - 24.4

0%

<11.0 = shorted

<22.0 = shorted

Note:

 All OPTIMA brand starter/deep cycle batteries have a fully charged 

“resting” voltage of 13.1 (OCV).  Increase above values accordingly. 

Summary of Contents for 128CEC1

Page 1: ...attery Maintainer Desulfators Quick Start and Safety Manual All Models Include ATS Temperature Sensor installed Ring Terminals with 15A Fuse Insulated Battery Clip cordset with quick connect plug NOT...

Page 2: ...age to electric plug and cord pull by plug rather than cord when disconnecting charger Make sure cord is located so that it will not be stepped on tripped over or otherwise subjected to damage or stre...

Page 3: ...attention immediately 5 NEVER smoke or allow a spark or flame in vicinity of battery or engine 6 Be extra cautious to reduce risk of dropping a metal tool onto battery It might spark or short circuit...

Page 4: ...t be mounted in this manner to ensure long term trouble free life including weatherproof integrity Mounting in any other manner or using un mounted parallel to ground except indoors may cause unit to...

Page 5: ...POS P post of battery 4 Position yourself and free end of cable as far away from battery as possible then connect NEGATIVE BLACK charger clip to free end of cable 5 Do not face battery when making fin...

Page 6: ...istilled water only to the liquid level indicator found in each cell Before proceeding further you must be thoroughly familiar with the safety and operating instructions 4 Recharge the battery with th...

Page 7: ...readings Be certain to read and understand all safety related instructions pages 2 to 7 before proceeding further 2 Measure battery s voltage without any load attached If the voltage is less than 12 4...

Page 8: ...PLT Load Light ON Float Battery 22V 4A 2A 1A Float Battery 24V 4A 2A 1A Float Battery 26V 4A 2A 1A Float Battery 26V 4A 2A 1A For 244CEC1 model please refer to actual unit 128CEC1 Load Light OFF Soft...

Page 9: ...AC power connected Green Flashing ECO mode BATTERY CONNECTION GREEN RED Green Steady Battery connected correctly Red Steady Battery connected incorrectly BATTERY WEAK AMBER Amber Steady Battery requi...

Page 10: ...nstant Voltage stage and every 12 hours while in Float Float sometimes called Maintenance is the charger s long term stage The charger can and should be left connected indefinitely This will keep the...

Page 11: ...ambient temperature sensor which allows it to vary the output voltage as necessary to properly charge your 12V 0 025 V C or 24V 0 050 V C battery Batteries charged at higher temperatures without comp...

Page 12: ...of purchase ___________________________ RMA ___________________________ Please register your unit on line within 10 days of purchase Due to the ever changing technology associated with this BatteryMI...