background image

BCA1123 

– 140729                                                       

 

 

 

SELECTION FOR BATTERY TYPE   

A.C. power is connected with the wall socket properly 

Press 

MODE

 button for battery charge mode selection before you connect the charger to the battery terminals.   

 

LED Signal   

Explanation 

Description 

LifePO4 

LiFePO charging   

 
Lithium iron phosphate (LiFePO4) battery charge 
mode 

LiPO 

LiPO charging 

 
Lithium polymer (LiPO) battery charge mode 

12V 12A 

Lead Acid charging   

 
12V lead acid battery charge mode at 12A max. 

12V 3.8A 

Lead Acid charging   

 
12V lead acid battery charge mode at 3.8A max. 

 

LIGHT INDICATION: 
1)

 

Pb Charging mode    (Lead–acid battery charging mode 

   

 

LED SIGNAL 

EXPLANATION 

POWER 

A.C. power is connected with the wall socket properly and self-test will be commenced, the LEDs 

will be flashing in following sequence - Reverse Polarity LED -> 12V 3.8A LED -> Bad Battery 

LED -> 12V 12A LED -> Recovery LED -> Li-Po LED. After completed the self-test, it will enter 

into standby mode. Standby : POWER LED is flashing ; Charging : POWER LED is glowing   

MODE 

Press the MODE button for the selection of charging program. 

12V 3.8A 

PB charging status : the charger is switched to 12V lead acid (Pb) battery charging mode with 

maximum current 3.8A 

12V 12A 

PB charging status : the charger is switched to 12V lead acid (Pb) battery charging mode with 

maximum current 12A 

REVERSE POLARITY 

Battery is connected in reverse polarity, please check the battery connection(s) and correct 

reverse polarity condition. ( Make sure Red to “+” and Black to “-”)   

RECOVERY 

Battery Recovery processes will commence if the charger detects any charge acceptance 

problems. Recovery processes include: Battery Rescue Phase, Soft Start Phase, Pulse Mode 

Phase and Recondition Phase. Once the Recovery processes are completed, normal charge will 

commence immediately. Recovery function in effect for Lead Acid charging mode (12V 12A; 12V 

3.8A) only. 

FULLY CHARGE / 

MAINTENANCE 

The charging process is completed and the battery is in maintenance mode, it can be returned to 

service if necessary or left safely connected to the charger indefinitely. Maintenance function in 

effect for Lead Acid charging mode (12V 12A; 12V 3.8A) only. The LED will be flashing while 

approaching fully charged and glowing in fully charge or maintenance stage 

BAD BATTERY 

The battery is worn out or is possibly defective. Suggest replacing battery ASAP 

Summary of Contents for BCA1123

Page 1: ...mage or stress 9 Study all the battery manufacturers specific precautions such as removing or not removing cell caps while charging and recommended rates of charge 10 Do not use the battery charger un...

Page 2: ...attery acid to drip on the charger when reading gravity or filling battery d Do not operate charger in a closed in area or restrict ventilation in any way e Do not set a battery on top of charger CONN...

Page 3: ...recognizes at least three volts from the battery The battery charger clips must be clipped to a battery in the correct polarity to initiate output voltage and begin charging when in Lead Acid Pb char...

Page 4: ...charging status the charger is switched to 12V lead acid Pb battery charging mode with maximum current 3 8A 12V 12A PB charging status the charger is switched to 12V lead acid Pb battery charging mod...

Page 5: ...thium Polymer battery charge mode REVERSE POLARITY Battery is connected in reverse polarity please check the battery connection s and correct reverse polarity condition Make sure Red to and Black to R...

Page 6: ...d ensure they are good B Check to ensure that there is power at the AC outlet by plugging in a table lamp or power meter Power Light On but the charging light is off A Battery is not connected B The b...

Page 7: ...en the charger has detected a battery at a very low initial state of charge Voltage and current are delivered at a specified rate to help the battery to recover prior to entering pulse charge mode 4 P...

Page 8: ...attery Recovery Processing 4 Stage LiFePo4 LiPO Charge Process 1 Qualification Phase Once the charger has been properly connected to the battery it will deliver a constant pulse frequency to activate...

Page 9: ...Yes Spark Proof Yes Overload Protection Yes Reverse Polarity Protection Yes Over Heat Protection Yes Battery Capacity Charging LEAD ACID 12V 3 8A MAX 240 Ah 12V 12A MAX 480Ah Maintenance all sizes For...

Reviews: