BCA1123
– 140729
SELECTION FOR BATTERY TYPE
A.C. power is connected with the wall socket properly
Press
MODE
button for battery charge mode selection before you connect the charger to the battery terminals.
LED Signal
Explanation
Description
LifePO4
LiFePO charging
Lithium iron phosphate (LiFePO4) battery charge
mode
LiPO
LiPO charging
Lithium polymer (LiPO) battery charge mode
12V 12A
Lead Acid charging
12V lead acid battery charge mode at 12A max.
12V 3.8A
Lead Acid charging
12V lead acid battery charge mode at 3.8A max.
LIGHT INDICATION:
1)
Pb Charging mode (Lead–acid battery charging mode
)
LED SIGNAL
EXPLANATION
POWER
A.C. power is connected with the wall socket properly and self-test will be commenced, the LEDs
will be flashing in following sequence - Reverse Polarity LED -> 12V 3.8A LED -> Bad Battery
LED -> 12V 12A LED -> Recovery LED -> Li-Po LED. After completed the self-test, it will enter
into standby mode. Standby : POWER LED is flashing ; Charging : POWER LED is glowing
MODE
Press the MODE button for the selection of charging program.
12V 3.8A
PB charging status : the charger is switched to 12V lead acid (Pb) battery charging mode with
maximum current 3.8A
12V 12A
PB charging status : the charger is switched to 12V lead acid (Pb) battery charging mode with
maximum current 12A
REVERSE POLARITY
Battery is connected in reverse polarity, please check the battery connection(s) and correct
reverse polarity condition. ( Make sure Red to “+” and Black to “-”)
RECOVERY
Battery Recovery processes will commence if the charger detects any charge acceptance
problems. Recovery processes include: Battery Rescue Phase, Soft Start Phase, Pulse Mode
Phase and Recondition Phase. Once the Recovery processes are completed, normal charge will
commence immediately. Recovery function in effect for Lead Acid charging mode (12V 12A; 12V
3.8A) only.
FULLY CHARGE /
MAINTENANCE
The charging process is completed and the battery is in maintenance mode, it can be returned to
service if necessary or left safely connected to the charger indefinitely. Maintenance function in
effect for Lead Acid charging mode (12V 12A; 12V 3.8A) only. The LED will be flashing while
approaching fully charged and glowing in fully charge or maintenance stage
BAD BATTERY
The battery is worn out or is possibly defective. Suggest replacing battery ASAP