Bath Authority DreamLine Neptune Installation Instructions Manual Download Page 17

 

Performance

 

z

  The control uses a blue color back light liquid crystal display with white back light 

induction type touching key. 

z

  Turning the steam on will fill the generator with water automatically; when system is 

shut-down an automatic water draining system is turning on. 

z

  Includes steam and light control functions 

z

  Steam temperature regulation range: Centigrade temperature 30~60C, Fahrenheit  

86~140F; Steam time regulation range: 0~60 minutes 

z

  Automatic temperature controls also include tracking of excess temperature, over 

pressure and power leakage protection function. 

 

Operation Instructions:

 

—

  Switch-on: Push the power switch, the present cabin temperature is shown on the 

display, the top light turns on, and the system stays in the stand by mode.

 

—

  Steam: Push the steam key directly to turn steam function on or off.

 

—

  Temperature-set: Push temperature setting key, pre set temperature is shown on the 

screen. Push the “tempe” or “temperature –“key to get the temperature you 
desired. The temperature will gradually increase or decrease within 86~140F (30 ~ 
6

0℃

)

.

 “Celsius” displays the Celsius temperature; “Fahrenheit” displays Fahrenheit 

temperature. If the temperature in the cabin is higher than that the temperature you 
try to set, the steam generator can not be started. 

—

  Time-set: Push the time setting key and the steam generator and control go into the 

time-set mode; push the “time +” or “time –“key to get desired time of the steam bath. 
The time range is 5~60 minutes. 

—

  Lighting: Push the light key, and the light can be switched on or off. 

—

  Switch-off: Push the power key and switch off all the functions.

 

 
If not using steam options/control for a long time – turn off the power main electric 
supply of the units. 

 
 
Warning 
 

™

 

Do not connect this steam shower with other electric appliances not recommended by 
DreamLine™, and do not take apart the sealed lines or the electric lines from the 
power box.  

™

 

A drainage pipeline shall be fixed to auto-drain valve of the main steam generator, and 
it’s better to add a water filter before the water entrance to increase generator’s 
service life. 

™

 

The steam generator should be working with water hardness levels 60-120 mg/l. If 
hardness of your water more then recommended it can cause "scale" (mineral build up 
in pipes and plumbing fixtures). Scale can cause of your steam unit damage. You 
need to treat your water. Water softeners are the most frequently used of all water-
conditioning devices and are installed for reducing hardness for private wells and 
utility supply with high levels of calcium or magnesium. 

™

 

The line from the power box shall be plugged according to the digit capacity and the 
size. Do not short circuit. 

™

 

The steam generator is complicated option and shall be installed by the qualified and 
authorized technical persons. 

 

DreamLine™ shall not be responsible for negative consequences due to any 
incorrect installation or improper operations per instructions listed above. 
 

Rev. 1. 3. 

17

Summary of Contents for DreamLine Neptune

Page 1: ...nstalling your shower cabin If you have any questions on this shower cabin installation please call our technical support specialists Monday to Friday 9 00AM 5 00PM EST at 1 866 731 8378 Option 3 or e...

Page 2: ...ed off any remaining hot water in the steam generator system is automatically drained into the shower cabin For your safety please do not turn off the power button on the control unit until you are re...

Page 3: ...lectric shock due to high voltage that runs in the equipment Follow these steps to avoid the risk of overheating or scalding 9 Exit the shower cabin immediately if you feel uncomfortable dizzy or slee...

Page 4: ...ation and DreamLine is not responsible for code compliance standards for your project 3 Install all of the required plumbing and drainage before securing the shower Use a competent and licensed if req...

Page 5: ...tionary glass 1pc 28 Flat head bolt M8 20 4pcs 10 Maintenance door 1pc 29 Washer 4pcs 11 Wall profile 1pc 30 Glass bracket 4pcs 12 Handle for maintenance door 1pc 31 Round head screw ST4 2 25 4pcs 13...

Page 6: ...panel 02 and the tray with Bolt M6 40 22 See Fig 5 and Fig 6 for details NOTE For steps 6 7 and 8 it will be necessary to apply silicone sealant between the panels and the panels and tray 7 Connect th...

Page 7: ...llow wire from the steam generator to the ground See Fig 24 and Fig 31 for details Use the corresponding electrical connection or plug according to the local power system standards 22 Remove the back...

Page 8: ...9 7 8 9 7 8 2 2 PVC pipe support Fig 1 Fig 2 41 3 4 4 47 1 4 power 1 2 screw connector 35 1 8 Fig 3 Fig 4 Rev 1 3 8...

Page 9: ...Fig 5 Fig 6 Fig 7 Fig 8 1 2 1 2 Rev 1 3 9...

Page 10: ...Fig 9 Fig 10 Fig 11 Fig 12 1 2 1 2 3 3 Rev 1 3 10...

Page 11: ...Fig 13 Fig 14 Fig 15 Fig 16 1 2 3 4 5 1 2 3 3 Rev 1 3 11...

Page 12: ...Fig 17 Fig 18 L L Fig 19 Fig 20 1 2 3 4 5 6 7 8 Rev 1 3 12...

Page 13: ...11 16 Fig 21 Fig 22 L1 L2 N L1 L2 N Fig 23 Fig 24 6 1 2 3 4 5 Blue Red Cool Red Rev 1 3 13...

Page 14: ...Fig 25 Fig 26 Fig 27 Fig 28 1 2 3 1 2 1 2 3 1 2 3 Rev 1 3 14...

Page 15: ...ater Fig 31 1 2 3 4 Control Panel Electronic Control Box Steam generator Power wire Steam wire Steam control wire Control panel cable Top light power cable Temperature probe Ground cable Steam outlet...

Page 16: ...erature for all valves you are using Mixer Valve z Valve a turns on water for the tropical rain head shower z Valve b turns on water for massage jets z Valve c turns on water for the waterfall head sh...

Page 17: ...et mode push the time or time key to get desired time of the steam bath The time range is 5 60 minutes Lighting Push the light key and the light can be switched on or off Switch off Push the power key...

Page 18: ...ch as acetone gasoline or thinners Do not use ammonia based cleaning solutions on the acrylic as it will eat into the surface and cause it to damage How do you get scratches out of Acrylic For light s...

Page 19: ...ood act of God or any other casu alty Improper care and cleaning will void the warranty Use of cleaners containing abrasive cleansers ammonia bleach acids waxes alcohol solvents or other products not...

Reviews: