background image

2

H19 Series BASO High Pressure Safety Pilot Valve Installation Instructions

Checkout

!

WARNING: Risk of Explosion or Fire.

Follow this or an equivalent checkout procedure
after installation. Before leaving the installation,
verify that the gas valve functions properly and that
the system has no gas leaks. Gas leaks can lead to
an explosion or fire, and may result in severe
personal injury or death.

Make sure all components are functioning properly by
performing the following test.

1.

Test all joints and connections for leaks with a
rich soap and water solution.

2.

Close the main upstream shutoff valve and wait at
least 5 minutes for unburned gas to escape from
the appliance, and then reopen the valve.

Note: If used with the BASO H19 high pressure
valve, continue through 6.

IMPORTANT:

When the reset button is

depressed, gas flows to both the main and pilot
burners on valves without the flow interruption
feature.

3.

Push the reset button on the H19 high pressure
valve and light the pilot burner. Continue to hold
the reset button for 30 to 45 seconds or until the
pilot burner flame continues to burn when the
button is released.

IMPORTANT:

Pilot burners cannot be used

without suitable high pressure valve.

4.

Extinguish the burner by closing the main
upstream manual shutoff valve. Verify that the
valve drops out within 90 seconds.

5.

Relight the pilot burner.

6.

Observe at least three complete operating cycles
to make sure that all components are functioning
properly.

Technical Specifications

Product

Y99HY Series Shutoff Valve

Types of Gas

2nd (Natural Gas) or 3rd (LP Gas) Family Gases

Permissible Ambient
(Surface) Temperature

-40 to 175ºF (-40 to 79ºC)

Maximum Operating
Pressure

50 psi (0.34 MPa)

Inlet Pipe Size

1/8 or 1/4 NPT

Outlet Pipe Size

1/8 or 1/4 NPT

Operating Time Rating

100% Continuous

Packaging

Bulk pack supplied to original equipment manufacturer (individual pack optional)

Bulk Pack Quantity

20 per carton

Bulk Pack Weight

Agency Listing

CSA Certificate Number 229521-70067751

Specification Standards

UL 125

Performance specifications are nominal and conform to acceptable industry standards. All agency certification of BASO products is performed
under dry and controlled indoor environmental conditions. Use of BASO products beyond these conditions is not recommended and may void
the warranty. Product must be protected if exposed to water (dripping, spraying, rain, etc.) or other harsh environments. The original
equipment manufacturer or end user is responsible for the correct application of BASO products. Consult BASO Gas Products LLC for
questionable applications. BASO Gas Products LLC shall not be liable for damages or product malfunctions resulting from misapplication or
misuse of its products.

1007 South 12th Street
PO Box 170
Watertown, WI  53094

www.baso.com

1-877-227-6427 (1-877-BASOGAS)

Published in U.S.A.