AW00123401000
Physical Interface
Basler ace USB 3.0
35
5.8.2
Electrical Characteristics
shows a schematic for the opto-isolated output line. See the previous section for
recommended voltages and their significances. The absolute maximum voltage is +30.0 VDC.
The
maximum current
allowed through the output circuit is
50 mA
.
Figure 18 shows a typical external circuit you can use to monitor the output line with a voltage signal
.
Figure 19 shows a typical circuit you can use to monitor the output line with an LED or an
pto-coupler. In this example, the voltage for the external circuit is +24 VDC. Current in the circuit
is limited by an external resistor.
For more information about output line pin assignments and pin numbering, see Section 5.2 on
.
For more information about the Exposure Active signal, see a following version of the manual.
Your
Gnd
Your
Gnd
+3.3 to +24
VDC
Camera
Voltage
Output
Signal
to You
Q1
1
6
3
4
2
5
Fig. 18: Opto-isolated Output Line Schematic with a Typical Voltage Output Circuit (Simplified)
Your
Gnd
Camera
Q1
1
6
3
4
2
5
Your Gnd
LED
Output
to You
+24
VDC
2.2k
Fig. 19: Opto-isolated Output Line Schematic with a Typical LED Output Signal at +24 VDC for the External Circuit
(Simplified)
Summary of Contents for acA1300-30um/uc
Page 4: ......
Page 8: ...Table of Contents AW00123401000 iv Basler ace USB 3 0...
Page 28: ...Installation AW00123401000 20 Basler ace USB 3 0...
Page 50: ...Physical Interface AW00123401000 42 Basler ace USB 3 0...
Page 54: ...Troubleshooting and Support AW00123401000 46 Basler ace USB 3 0...
Page 56: ...Revision History AW00123401000 48 Basler ace USB 3 0...