19
more than 10% of the measuring range and not less than
0.4m.
■
When flange mounting,plastic material flange is
recommended. It is best to specify the size of the installation
flange when ordering, direct preparation by the manufacturer.
If installed on metal flange or metal thread, please install
as above. To avoid resonance, resulting in measurement
errors (large measure liquid level than actual value)
■
In the case of a closed container, the flanges and short
tube on the container shall meet the following requirements:
■
Install the installation as far away from the uneven container
wall, away from the ladder in the container, sprue, mixing
Type
4m、6m、8m
12m、20m、30m
20m、30m Horn
Req
ui
re
m
en
t
Flange
diameter
should not be less
than 65mm,short
socket of the inner
wall is smooth and
large diameter,the
length should be
short, < 400mm.
Flange diameter should
not
be
less
than
100mm, flange socket
length should be less
than 150mm and the
inner wall is smooth.
The
probe
should
extend
from
the
mounting opening.
Flange
diameter
should not be less
than 200mm, flange
socket length should
be less than 200mm,
the probe should be
extended from the
mounting opening.