background image

Output Control 

9

 

Output operation 

 

The analog output
operates according 
to the values of parameters 

Low Limit

High Limit

,  

and

 

Output Value

 

The alarm relay output 
operates according  
to the control algorithm 
parameters - 

Set Point

Direction

, and

 

Hysteresis

 

When an error is detected,
the relay output deactivates 
and the analog output 
is held for a certain time, 
defined by the parameter 

Hold Time On Error

 

The analog output signal
in case of an error depends 
on the value of parameter 

Output On Error

ON/OFF control algorithm 

The static characteristic 
of an alarm relay controlled 
by an ON/OFF algorithm 
is shown on the left drawing. 

Summary of Contents for BCOT751

Page 1: ...SJ SWEDEN tel 46 0 40 88009 fax 46 0 40 929877 e mail info basi se BCOT751 OPERATION MANUAL Please read this Operation Manual before mounting and operating Save the Manual for future references SMART...

Page 2: ...n every 35 mm rail conforming to EN50022 Wiring Connect a conductivity cell to terminals 5 and 6 7 and a temperature compensation sensor to terminals 7 6 and 8 Terminals 6 and 7 are internally connect...

Page 3: ...nctionality is installed see Specifications Changing Point Position value reflects on the real value of all parameters with the conductivity measurement unit E g changing Point Position value from 0 t...

Page 4: ...Resistance of the connection wires Output Parameters Output Configuration o conf Analog output signal type Analog Output Link o lnk Defines input linked to the analog output Low Limit o lo Input valu...

Page 5: ...00000 1 cm 5 6 00 00 99 99 3 used for long wire resistance compensation i 0 20 i 4 20 u 0 10 u 2 10 i 0 20 0 20 mA i 4 20 4 20 mA u 0 10 0 10 V u 2 10 2 10 V cond temp cond conductivity input temp tem...

Page 6: ...ed in frames Each frame consists of 1 or 2 words separated by byte 32 SPACE and ends with bytes 13 CR and 10 LF The first word in the frame denotes the parameter Symbol as taken from Table 1 and the s...

Page 7: ...all incorrect memory 0 all no error 1 Cell Constant out of range 2 Filter Time out of range 3 Filter Band out of range 4 Temperature Coefficient out of range 5 Default Temperature out of range 11 Hyst...

Page 8: ...rn off temperature compensation set parameter Temperature Compensation to off t comp off 13 10 Input Filtration Low pass filter This first order filter acts ONLY within a certain band around filter ou...

Page 9: ...rs Set Point Direction and Hysteresis When an error is detected the relay output deactivates and the analog output is held for a certain time defined by the parameter Hold Time On Error The analog out...

Page 10: ...const x xxxxxx 13 10 Calibration by adjusting measured value To use this method set parameter Calibration Mode to c cal cal c cal 13 10 To take temperature compensation into account select the desire...

Page 11: ...together with household waste material If disposed of within European Union this product should be treated and recycled in accordance with the laws of your jurisdiction implementing Directive 2012 19...

Page 12: ...ng IP20 Warranty and Support article number serial number manufacturing date QC check mark passed stamp BASI Instrument AB p o box 53 SE 275 06 VOLLSJ SWEDEN tel 46 0 40 88009 fax 46 0 40 929877 e mai...

Reviews: