BASETech BT-200 Operating Instructions Manual Download Page 3

Intended use





Cable tester for unshielded (UTP) or shielded (STP/FTP) RJ-45 modular plug systems up to 

CAT7, respectively RJ-11 (RJ-12) modular plug with 2 to 6 cores. Each core of the connected 

cable is individually tested and the allocation is shown on a clearly arranged bar graph display. 

The test sequence is automatic. The allocation of the cores, respectively potential errors such 

as interruption and short circuit can be read directly.
In addition, the BNC coaxial cable can be tested for continuity, interruption and short circuit.
This product is intended for operation with a 9 V block battery.
Avoid contact with moisture.
Do not use the product under adverse ambient conditions. Adverse ambient conditions are:
-  dampness or excessive humidity,
-  dust and flammable gases, vapours or solvents,
-  thunderstorms or similar weather conditions such as strong electrostatic fields etc.
Any use other than that described above can lead to damage to the product and may involve 

additional risks such as short circuits, fire, electric shock etc. No part of the product may be 

modified or converted! The safety instructions are to be observed without fail!

Package contents





•  MASTER unit
•   REMOTE unit
•   BNC-REMOTE unit
•   9 V battery
•  Carrying bag
•  Operating instructions

Explanation of symbols





   The exclamation marks in these operating instructions indicate important indications.

 

   Carefully read the entire instructions before commissioning the product. They con-

tain important indications on correct operation.

  The “arrow” symbol points to special tips and operating indications.

Safety instructions





 

 Damage  due  to  failure  to  follow  these  operating  instructions  will  void  the 

warranty/guarantee! We assume no liability for subsequent damages! 

 

 We assume no liability for material damages or personal injuries caused by 

improper handling or failure to observe the safety instructions! In such cases, 

the warranty/guarantee is void.

 

•  In commercial institutions, the accident prevention regulations of the Employer’s 

Liability Insurance Association for Electrical Systems and Operating Facilities are 

to be observed.

 

•  In schools, training centres, hobby and self-help workshops, the use of the meas-

urement devices must be supervised in a responsible manner by trained person-

nel.

 

•  The unauthorised conversion and/or modification of the device is not permitted for 

safety and approval reasons (EC).

 

•  Extra care should be taken when using the device for the first time. Therefore, 

please follow the operating instructions carefully.

 

•  The device may not be exposed to extreme temperatures, strong vibrations or high 

air humidity. The display takes place in a temperature range from 0 °C to +50 °C.

 

•  The housing may not be disassembled, except to open the battery compartment.

 

•  Measuring devices are not toys and should be kept out of the reach of children.

Operating elements





1  Operating switch 
2  Operation indicator
3  BNC output jack
4  RJ-11 output jack
5  RJ-45 output jack
6  Slot for REMOTE unit
7  Key for MASTER unit
8  RJ-45 input jack
9  LED display MASTER
10 RJ-11 input jack
11  LED display REMOTE
12 Battery compartment lid on the backside
13 BNC remote unit

Inserting/replacing the batteries 





During the initial commissioning or if the operation indicator stops flashing, a 

new battery must be inserted.    
A 9 V block battery (type 6F22 or structurally identical) is required for opera-

tion. A battery is supplied with the device.
To insert/replace the battery, proceed as follows:
Slide the battery compartment lid of the MASTER unit towards the direction 

of the arrow.
Remove the used batteries from the battery compartment (12), if necessary. 

Connect a new battery with the battery clip, observing the right polarity. Insert 

the new battery into the battery compartment and carefully close back the 

battery compartment.

   You can order a matching replacement battery stating the order number 652509. 

Please order one time.

To prevent damage to the device through leaking batteries, remove the battery from the device 

if you do not need it for a longer period. For the same reason, it is advisable to remove empty 

batteries immediately.

   Do not leave batteries lying around unattended. They could be swallowed by 

children or pets. If they are swallowed, consult a doctor immediately.

 

 Batteries must not be charged, shorted or thrown into a fire. There is a risk of 

explosion.

Commissioning and operation





   

In order to ensure correct commissioning, you should read these operating 

instructions  including  the  safety  instructions  thoroughly  and  attentively 

before using the device!

The MASTER unit also powers the REMOTE unit via the cable to be tested. For this purpose 

the cable to be tested must have two functional cores. 
By means of the operating switch two testing speeds can be adjusted.
Switch position OFF:   Device is switched off

Switch position ON:  

Normal testing speed

Switch position S:  

Slow testing speed

Slide the switch to the appropriate switch position. 
The switching of cable core tested occurs automatically starting from 1 and repeats itself after 

the last cable core. The test interval is signalised by the operating display which is flashing 

during the test cycle.
The test always runs through the maximum possible display area. If a cable contains fewer 

cores (e.g. telephone lines etc.), only these areas are displayed.
The indication for the BNC connector is only via the LED with the label “B”.

   The MASTER unit and REMOTE units can be assembled to one unit by means 

of the lateral slot (6) and spring (7). This facilitates the handling when no cable is 

installed.

 

 For  this,  slide  the  key  of  the  REMOTE  unit  (7)  from  above  into  the  slot  of  the  

MASTER unit (6).

Testing of RJ-11 and RJ-45 Cable

RJ-11/RJ-12:

When checking the RJ-11/RJ-12 cables, plug the two plugs of the cable to be tested into the 

jacks with the label “RJ-11” (4 and 10).
The display corresponds to the light marked area of LEDs 1 to 6.

 

Operating instructions

Cable Tester BT-200

Item no. 1367588

Version 08/15

°

Summary of Contents for BT-200

Page 1: ...4 RJ 11 Ausgangsbuchse 5 RJ 45 Ausgangsbuchse 6 Nut für REMOTE Einheit 7 Feder für MASTER Einheit 8 RJ 45 Eingangsbuchse 9 LED Anzeige MASTER 10 RJ 11 Eingangsbuchse 11 LED Anzeige REMOTE 12 Rückseitiger Batteriefachdeckel 13 BNC Remote Einheit Einlegen Wechseln der Batterien Bei Erstinbetriebnahme bzw wenn die Betriebsanzeige nicht mehr blinkt muss eine neue Batterie eingesetzt werden Zum Betrieb...

Page 2: ...MASTER Einheit und keine Anzeige an der BNC Remote Einheit Die Betriebsanzeige blinkt je Durchlauf 10x jedoch erfolgt keine Anzeige B Die LED der BNC Remote Einheit bleibt dunkel Kurzschluss Verbindung Bei einem Kurzschluss erfolgt nur die Anzeige B an der MASTER Einheit Die Anzeige der BNC Remote Einheit bleibt dunkel Nachdem die Betriebsanzeige 9x blinkt erfolgt die Anzeige B an der MASTER Einhe...

Page 3: ... indicator 3 BNC output jack 4 RJ 11 output jack 5 RJ 45 output jack 6 Slot for REMOTE unit 7 Key for MASTER unit 8 RJ 45 input jack 9 LED display MASTER 10 RJ 11 input jack 11 LED display REMOTE 12 Battery compartment lid on the backside 13 BNC remote unit Inserting replacing the batteries During the initial commissioning or if the operation indicator stops flashing a new battery must be inserted...

Page 4: ... obligations and contribute to the protection of the environment Technical data Power supply 9 V block battery 6F22 1604 or structurally identical Current consumption approx 12 mA Measuring principle electrical resistance Cable type RJ 45 CAT 5 CAT 6 CAT 7 STP FTP shielded UTP unshielded Cable type RJ 11 RJ 12 6P6C 6P4C 6P2C Cable type BNC Coaxial Cable length max 300 m Operating conditions 0 C to...

Page 5: ...es jouets et ne doivent pas être laissés à la portée des enfants Organes de commande 1 Interrupteur de service 2 Indicateur de fonctionnement 3 Prise de sortie BNC 4 Prise de sortie RJ 11 5 Prise de sortie RJ 45 6 Rainure pour l unité DISTANTE 7 Ressort pour l unité MAÎTRE 8 Prise d entrée RJ 45 9 Affichage LED MAÎTRE 10 Prise d entrée RJ 11 11 Affichage LED DISTANTE 12 Couvercle du compartiment à...

Page 6: ... La LED de l unité distante BNC reste sombre Court circuit liaison En cas de court circuit seul l affichage B est visible sur l unité MAÎTRE L affichage de l unité distante BNC reste sombre Après 9 clignotements de l affichage de service l affichage B apparaît sur l unité MAÎTRE La LED sur l unité distante BNC reste sombre Mise à l arrêt Pour éteindre poussez l interrupteur de service sur la posit...

Page 7: ...2 Werkingsindicator 3 BNC uitgangsconnector 4 RJ 11 uitgangsconnector 5 RJ 45 uitgangsconnector 6 Groef voor AFSTANDseenheid 7 Veer voor HOOFDeenheid 8 RJ 45 ingangsconnector 9 LED indicator HOOFD 10 RJ 11 ingangsconnector 11 LED indicator AFSTAND 12 Deksel van het batterijvak aan de achterkant 13 BNC afstandseenheid Plaatsen vervangen van de batterijen Bij de eerste ingebruikname resp als de stro...

Page 8: ...afstandseenheid De werkingsindicator knippert 10x bij elke doorloop maar er volgt geen weergave van B De LED van de BNC afstandseenheid blijft donker Kortsluiting Verbinding Bij een kortsluiting gebeurt de weergave B enkel op de HOOFDeenheid De LED van de BNC afstandseenheid blijft donker Nadat de werkingsindicator 9x knippert volgt de weergave van B op de HOOFDeenheid De LED van de BNC afstandsee...

Reviews: