background image

Basementsaver Battery Powered Backup Sump Pumps -

 

www.basementsaver.com

 - 

Call 716.775.0206

 

 

Updated Jan 2016 

Basementsaver BP3 Battery Powered Backup Sump Pump 

Step By Step Installation Instructions 

 

NOTE:

The 

Basementsaver BP3 Backup Pump

 Is A Very Powerful Sump Pump.  

Use Teflon tape or 

pipe sealant (dope) on ALL threaded fittings. Use PVC Primer & Cement on ALL socket joints. 

 
You may choose to install the BP3 using two size 27 marine deep cycle batteries which will double your 
total pumping capacity for extended pumping times. An extra BCC battery case and cables is available. 
 

BP3 Installation Diagram   

 

 

 

  Wiring Schematic 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Step 1 - BP3 Pump Unit Assembly: 

Remove all packaging and materials and hang all wires over the side and out of the battery box(es). 
Before placing the pump into the sump pit, find the 1½

” PVC male threaded adapter, 1½” pipe with vent 

hole, check valve, PVC Female adapter, and straight black polypro barbed male hose adapter. 

  Cement the 1½

” PVC male threaded adapter onto the 

bottom end

 (

with 

vent hole

) of the pipe. 

 

Let the PVC cemented joint set.

 

  Screw this pipe assembly into the sump pump discharge opening (in the sump pump base).

 

Hint 

– installing PTFE (Teflon) tape on the discharge pipe screw threads will help

 

  Cement the 

top end

 of the pipe (

without 

vent hole

) into the bottom of the check valve. 

The flow arrow on the Check Valve MUST point upward

  Cement the spigot end of the PVC female adapter into the top of the check valve. 

Do NOT drip glue into the check valve!

 

 

Let the PVC cemented joints set.

 

  Thread the male pipe threads of the straight black polypro barbed male hose adapter into the 

female threaded opening of the adapter that you just glued into the top of the check valve. 

You may double total pumping capacity by 

using 2 batteries to power your BP3 battery 

backup sump pump. 

BP3 Backup 
Sump Pump 

 

NOTE THE 
Vent Hole 

Summary of Contents for BP3

Page 1: ...er we re here to help you Basementsaver BP3 Low Maintenance Battery Powered Emergency Basement Sump Pump System For Commercial Sump Pits With Very High Pumping Rate Basementsaver BP3 Emergency Battery Powered Backup Sump Pump Removes 3 000 gal hr Average From Your Sump Pit Assuming A 10ft Lift To Discharge This Very Powerful Battery Backup Pump Is Designed To Fit Beside Or Above Your Existing Prim...

Page 2: ...without battery 11 Lb Float Switch Vertical Style with mounting clamp Total shipping weight 35 Lbs High Water Alarm 85 dBA 9VDC 2 or 1 PVC Discharge Capable Battery Requirements 12V Marine deep cycle or Sealed Lead acid Size 27 NOT Included Basementsaver BCC Optional Extra battery case is available to double pumping time at the same pumping rate Flow Rates Pumping Times At 5 feet 3300 Gallons Per ...

Page 3: ...eaded adapter 1 pipe with vent hole check valve PVC Female adapter and straight black polypro barbed male hose adapter Cement the 1 PVC male threaded adapter onto the bottom end with vent hole of the pipe Let the PVC cemented joint set Screw this pipe assembly into the sump pump discharge opening in the sump pump base Hint installing PTFE Teflon tape on the discharge pipe screw threads will help C...

Page 4: ...and back into your sump A removable type check valve is recommended in order to service the main pump in the future without disconnecting the backup pump For A 1 PVC Discharge Line Glue the bushings provided into the Tee fitting If you are using a 2 discharge they are not needed so set them aside For A 2 PVC Discharge Line Thread the male bushing into threaded opening of the 2 Tee and connect the ...

Page 5: ...nnect from one battery to the other using the Red cable to each positive battery terminal and the Black cable to each negative battery terminal See the wiring schematic on page 3 Pump Float Inverter Connections The float is supplied with a piggyback type plug The sump pump is to be plugged into the piggyback plug of the float and together both are plugged into ONE of the inverter outlets Charger O...

Page 6: ...operation Battery terminals may be connected improperly Correct and tighten securely 3 2 The Inverter Dispersion Of Heat The inverter will get warm during extensive operation This indicates that the unit is functioning properly The amount of heat generated will vary with the power draw of the backup pump In order for proper heat dissipation to occur ensure that air is allowed to circulate freely a...

Page 7: ... this Basementsaver Battery Powered Backup Sump Pump against defects in material and workmanship for a period of 2 Years from the date of the shipment In the event of any defect in the pump unit within the warranty period The manufacturer will at its option replace or recondition the product without charge providing the product is returned prepaid to our warehouse in Buffalo New York This shall co...

Reviews: