Mistakes and shortcomings

The equipment has been checked for normal function several times during the production process.
If the fault still occurs, please check the equipment according to the following list.

Warning
Electric shock is life-threatening!

Before performing any operation on the device, please unplug the power plug from 
the socket. Do not bypass any electrical safety devices!

!

Problem

Cause

Device does not work

The fuse is blown

The power plug 
is damaged

Solution

Replace the damaged fuse and/or 
reopen the fuse. Be careful! The fuse 
does not need to be repaired, but it 
must be replaced at any time. In most 
cases, the fuse is triggered by a serious 
technical failure. Please authorized 
service personnel to replace each fuse!

Let certified personnel inspect the 
equipment

.

Loud noise

Disconnect the power supply of the 
device and check whether the power 
plug and connecting cable are damaged

.

Plug the plug into the socket.

The connection 
parameters do not match 
the technical 
specifications

Check the connection to the main line.
Connection parameters: 110 V/ 60Hz.

Even if the cleaning 
process has been 
completed, the odor 
pollution still persists with 
the same intensity

Send the equipment to a certified 
professional workshop for repair

.

This device is placed in 
an uneven place

.

Reactor damage

Power is not turned on

Damage to the fan and/or 
its bearings

.

Place the device on a flat, solid, dry 
surface

.

In order to ensure the normal operation and trouble-free operation of the equipment, it must be cleaned 
and maintained regularly.

Summary of Contents for UVC2 Pro

Page 1: ...Installation Operations Manual UVC2 Pro Ozone Generator Tel 1 888 641 8862 Web www baseaire com E mail sales baseaire com...

Page 2: ...Table Of Contents Device Description Operation Mistakes and shortcomings Maintenance Transportation And Storage Technical Annex Electrical wiring diagram Limited Warranty 01 02 04 05 06 07 08 09...

Page 3: ...s by killing viruses bacteria molds and carcinogenic allergenic microorganisms The ozone generator sucks in the surrounding air and performs a discharge procedure After that energy breaks the diatomic...

Page 4: ...to the power source Observe the technical parameters Place the UVC2 Pro Ozone Generator in the center of the room Make sure that the equipment and connecting cables are not damaged Set the timer to t...

Page 5: ...the processing time Type Of Smell The treatment time is in min 3 Room size 30 m 20 30 30 60 60 80 350 360 360 3 3 30 m Room size 60 m 40 60 60 85 85 85 500 720 720 Disinfectant Car Interior From Anim...

Page 6: ...l failure Please authorized service personnel to replace each fuse Let certified personnel inspect the equipment Loud noise Disconnect the power supply of the device and check whether the power plug a...

Page 7: ...Regardless of the operating conditions described you should perform maintenance if one or more of the following signs appear Severely polluted soft magnetic stickers Dirty electrodes identifiable by h...

Page 8: ...ne generator in a dry place to avoid the influence of bad weather and cover it to protect it from invasive dust When the equipment is not in use always disconnect the power supply Clean Electrode Use...

Page 9: ...rating Temperature Sound Pressure Level Service Life Size For Dimensions l w h Minimum Distance From Walls And Other Objects Top a Rear b Sides c Front d Value 110V 60HZ 55 130CFM 220CMH 7 000 mg h 14...

Page 10: ...8 Electrical wiring diagram...

Page 11: ...ack to the BaseAire warehouse at the expense of the customers if customers are not available If the unit can no longer be fixed and it is in the warranty period and determined to be valid claim we wil...

Page 12: ...nection with BaseAire warranty thoroughly voids all warranty policies BaseAire expressly reserves the right to pursue legal action in the event of dishonesty fraud or attempted fraud THE WARRANTIES AN...

Reviews: