background image

Configuration through graphical interface

 –  

10

https://wiki.bas-ip.com/aa07v4/en/advanced-8552667.html

The address book is opened by clicking on the arrow buttons 

 or    and call is made by pressing

 

the "#".

The exit to the main screen is carried out by pressing "*" or automatically, after 30 seconds of 
inactivity.

By default, address book is disabled.

The tips displayed on the main screen can be changed in the "

Advanced 

 Custom 

Notifications

2

" section.

Device settings

To enter the system settings, press the "#"

 button twice: 

Next you need to enter 6 digits of the password to enter the call panel settings (default 
password: 123456

) and press  

"#".

Apartments are sorted by name.

Summary of Contents for AA-09 Series

Page 1: ...AA 09 AA 09 Exported on 07 11 2019 ...

Page 2: ... settings 12 Access settings 13 Additional settings 14 About system 15 Configuration through web interface 17 Login 17 Dashboard 18 Network information 19 Network 19 Network settings 19 Custom NTP 20 Management system 20 Panel 20 Apartment Settings 20 SIP settings 21 Call settings 22 Device settings 22 Apartments 23 New apartment 24 Access management 25 Common settings 26 Locks management 26 ...

Page 3: ...0 Device language 41 Software upgrade 41 Reboot 42 Installation and connection 43 Completeness check of the product 43 Electrical connection 43 Mechanical mounting 47 Connection of additional modules 48 Usage of the device 49 UKEY mobile access 49 Description 49 Working principle 49 Mobile access with UKEY applicationhttps wiki bas ip com basipidapp 49 Triple clicking setup with UKEY Cfghttps wiki...

Page 4: ... 4 Recieving the RTSP stream from the panel s camera 53 ...

Page 5: ...ion see page 6 Technical parameters see page 7 Configuration through graphical interface see page 9 Configuration through web interface see page 17 Installation and connection see page 43 Usage of the device see page 49 ...

Page 6: ...09B GOLD multi apartment panel is an excellent solution for office buildings apartment complexes and cottage communities A distinctive feature of this panel is a color TFT screen with backlight as well as a high resolution IP camera with large viewing angles Apperance ...

Page 7: ...ion 189 315 50 mm Size of the panel 250 328 48 mm Installation Type Flush Keypad Backlight mechanical buttons Functionality Interface Russian English WEB interface Opening the lock From the monitor by code by card from the BAS IP Intercom application UKEY Access Control AA 09E SILVER EM Marin Contactless Card Reader Access Control AA 09M SILVER Mifare Contactless Card Reader Access control AA 09B ...

Page 8: ...Technical parameters 8 Authentication Separate password for settings WEB interface Talk mode Duplex Optional SIP P2P Built in Relay ...

Page 9: ...you need to enter from 4 to 10 digits depending on the current mode of the panel Concierge to call concierge you should enter 0000 or press separate call button on the keypad Open to go to the Access Code menu press enter the access code and press to confirm To cancel an action or navigate through the menu you should press Address book A list of contacts to search for and call residents if the exa...

Page 10: ...n is carried out by pressing or automatically after 30 seconds of inactivity By default address book is disabled The tips displayed on the main screen can be changed in the Advanced Custom Notifications2 section Device settings To enter the system settings press the button twice Next you need to enter 6 digits of the password to enter the call panel settings default password 123456 and press Apart...

Page 11: ...ation through graphical interface 11 The 2 button moves the cursor up the 8 button moves the cursor down To confirm the values press the button and the button to go back Mode select operation mode of the panel ...

Page 12: ...apartment number to call the desired monitor If you select the Unit mode you must enter only 2 digits of the floor number and 2 digits of the apartment number to call the desired monitor You shouldn t select individual opreration mode for these panels It is used only for individual panels The number of the building and the unit should correspond to values of the internal monitor that will receive ...

Page 13: ...Subnet mask Gateway Default gateway DNS Address of the DNS server Server IP address of your PC or server where Management Software or Link software is installed Access settings When you switch to Access settings menu the following interface will be displayed By default the outdoor panel can have a static IP address 192 168 68 90 or 192 168 1 90 ...

Page 14: ... Elev Refer Floor number where the panel is installed using elevator control module EVRC IP optional Password Password to open the lock by entering the unlocking code on the panel keypad To enter the password input mode press the key type the password and press again Additional settings When you switch to Additional settings the following interface will be displayed Access pasword could be from 1 ...

Page 15: ... it is necessary to enter press 1 and then press again About system After switching to About system menu the following interface will be displayed Adding cards through graphical interface Enter the desired apartment number and wave the card in front of the area of the reader A signal will sound from the panel confirming that the card is registered and a card number will be displayed in the Card fi...

Page 16: ...Configuration through graphical interface 16 This window displays the current status of the SIP connection the current IP address the MAC address and the current firmware version ...

Page 17: ...ted to the same network segment as the PC from which you plan to configure In the Internet browser you must enter the IP address of the panel into the address input line A window will then appear to enter the username and password Username to enter settings admin or manager Administrator has full access to all panel settings Manager has access to the panel settings but he has limited access to the...

Page 18: ...zation the following interface will be displayed Framework Firmware version Launcher Launcher version Hybrid Mode The current connection mode of the hybrid adapter Hybrid Version Hybrid adapter version Serial number Serial number of the device Device name Name of the device ...

Page 19: ...k Gateway Address The address of the main gateway DNS server DNS server address MAC address MAC address of the panel Network Network settings DHCP Enable disable mode to get network settings automatically IP Outdoor panel IP address Mask Subnet Mask Gateway The main gateway Default values By default the outdoor panel can have a static IP address 192 168 1 90 or 192 168 1 91 ...

Page 20: ...s Time Zone Select the time zone Management system Mode Selects the operation mode of the panel control system URL Management server address Password Access password Send realtime logs to server Enable disable panel logging to server Send status to server Enable disable sending current panel status to server Panel Apartment Settings Mode select operation mode of the panel ...

Page 21: ...es If you select the Wall mode you must enter 4 digits of the building number 2 digits of the unit number 2 digits of the floor number and 2 digits of the apartment number to call the desired monitor If you select the Unit mode you must enter only 2 digits of the floor number and 2 digits of the apartment number to call the desired monitor If you have more than one outdoor panel you need to specif...

Page 22: ... time The time interval after which the panel automatically ends the outgoing conversation Auto call after N digits The function of automatic dialing after entering the digits specified in the line Number of digits Number of digits Select the number of digits which when pressed will automatically call from the panel Device settings Example stun l google com Example For google STUN server 19302 por...

Page 23: ...ername Login to get access to RTSP stream RTSP password Password to get access to RTSP stream Approximation sensor Enable disable the approximation sensor which turns on the keyboard backlight when triggered Apartments This menu displays a list of apartments An apartment is a logical entity intended to bind identifiers access codes and redirection rules Use the address book Enable disable usage of...

Page 24: ...layed Building Unit Floor Apartment Apartment name Apartment name For example Smith s Number of inhabitants The conditional number of inhabitants who live in this apartment After clicking on the Confirm button the following table will be displayed Building number 0001 9999 Unit number 00 99 Floor number 00 99 Apartment number 01 99 ...

Page 25: ...fiers that are issued for this apartment Identifiers can be created in the Access management menu tab Identifiers Number of access codes The number of access codes issued for this apartment Number of redirects The number of redirects configured for this apartment Actions Editing or deleting an apartment Access management In this menu you can set general control parameters of the access control sys...

Page 26: ...terface Enter 0 in the Master Card field and click the Apply button Next bring the master card necessary for registration to the panel reader area the text message Admin Key will be displayed and the signal BEEP will sound which means that the master card has been successfully registered After that in the area of the panel reader hold the user cards in turn After each user card the BIP signal will...

Page 27: ... Open lock The function of opening the selected lock from the panel WEB interface Additional settings Floor number elevator control The number of the floor on which the panel is installed for identification by the elevator module The function works when using the appropriate elevator control module Monitor secure mode Turns off the alarm on the internal monitor when you bring up a card that is con...

Page 28: ...el will send a request to the server and wait for the answer to give access or not Use a custom server Enable disable the use of custom server to control the panel Custom server server The custom server URL address Identifires This menu displays a table of identifiers and access codes added to the multi apartment panel memory New identifier After clicking on the New identifier button the following...

Page 29: ...Select the lock to open Access restrictions In this menu the access restrictions are set according to which the level of access of various users and their identifiers will be determined There are 3 types of identifiers available Card EM Marin or Mifare card In the next field ID number you must enter the ID number in decimal format without comas This ID usually is printed on the card How to tranfer...

Page 30: ...ion through web interface 30 New restriction After clicking on the New restriction button the following interface will appear Name The name of the rule All day Enable disable the time restriction interval per day ...

Page 31: ...gh web interface 31 Start at End at Select the interval of action for this restriction Repeat Specify the duration of repetitions of this restriction If function is disabled user can set time interval of this restriction ...

Page 32: ...If you select the Infinitely option rule will always act If you select the Until option you can set the end date for the action of this restriction Forward This section is used to substitute numbers by panel when making calls to internal monitors when there is no monitor or it is turned off or to any given SIP number ...

Page 33: ... the call is made to all numbers simultaneously One by one the call is made to the numbers in turn with a delay of 20 seconds New forward queue After clicking on the New Forward button the following interface will be displayed Apartment number Number dialed on the panel s keypad ...

Page 34: ...n of viewing additional IP cameras during a call up to 4 streams This feature is available for v4 monitors and any other SIP devices with a keyboard Input format for internal calls sip 1 192 168 1 65 where 1 is the desired number to be displayed by the called party 192 168 1 65 is the IP address of the called SIP client in the case of using a softphone the IP address of the device where the softph...

Page 35: ...dio message In this menu the text and sound file for each action can be changed to custom Also there is an ability to change the text displayed on the main screen of the panel During a call it is possible to switch between streams by pressing keys from 1 to 5 in the monitor menu The key 1 corresponds to the stream of the outdoor panel the keys from 2 to 5 to additionally added streams transmission...

Page 36: ... Channels mono Bit rates 16 Sample Rate 8000 Hz Key pressing Sound when you press the panel keys Message text The text displayed on the main panel screen In this field you can enter for example the number of the concierge for communication or the name of the residential complex ...

Page 37: ... when panel make an outgoing call Door unlock Sound and the text message Welcome when panel receive a signal to open the lock Error Sound and text message Error when entering an unregistered subscriber number the lock opening code and the presentation of an unregistered identifier ...

Page 38: ... BAS IP Link or through third party software using API Logs In this section all actions what happened with a panel are displayed Security In this section you can can change admin and manager password In emergency mode locks connected to the panel are also opened If any of the functions is turned off the standard sound and the standard text message will be used ...

Page 39: ...rd The field to enter the current password New password The field to enter a new password Confirm The field to confirm the new password System In this section backup and restoration of the panel settings software update language change and software reboot are performed The manager can only change the manager s password The administrator can change the manager password and the administrator passwor...

Page 40: ...face 40 Settings Choose file Selecting the panel configuration file from the PC file system Set default settings Reset all panel settings to factory defaults Backup all settings Save and export configuration files Export Import data ...

Page 41: ...oosing the language of the device Software upgrade When importing data into the panel all data in the Apartments Forward Identifiers and Access restricitons tables will be deleted and replaced with new data without the possibility of restoring old data When exporting data from the panel a secured ZIP archive is created which contains all data from the Apartments Forward Identifiers and Access rest...

Page 42: ...rver or user server Update software Start software update Reboot Reboot Soft reset of the panel IMPORTANT Before each software update it is necessary to create a backup copy of the panel settings Features of the system backup When updating the system via WEB or a graphical interface a backup copy of all applications installed on the call panel is automatically created and all configuration files a...

Page 43: ... for connection of power supply lock and additional modules 1 pcs A set of plugs for connections 1 pcs Wrench set screws 1 pcs Electrical connection After verifying whether a device is complete you can switch to the connection step For connection you will need An Ethernet UTP CAT5 or higher cable connected to a network switch router Power supply at 12V 2 amps Wires must be brought for connecting t...

Page 44: ...stallation and connection 44 1 Connection scheme of electromagnetic lock using uninterruptible power supply UPS DP S 2 Connection scheme of electromagnetic lock using third party power supply for the lock ...

Page 45: ...Installation and connection 45 3 Connection scheme of electromechanical lock using uninterruptible power supply UPS DP S ...

Page 46: ...Installation and connection 46 3 Connection scheme of electromechanical lock using third party power supply for the lock ...

Page 47: ...f the outdoor panel it is necessary to provide a hole or a recess into a wall with dimensions 190 316 51 mm for flush mount dimensions of the bracket mounting box 189 315 50 mm It is also necessary to provide supply of a power cable additional modules and the local network ...

Page 48: ...nt panels Module to control two locks SH 42 Module to control elevator equipment EVRC IP Multiformat reader with the support of UKEY technology BME 03 Installation height recommendations The outdoor panel should be installed at a convenient height for you Approximate height of installation is 160 165 cm of the camera level ...

Page 49: ...C Ability to use a cell phone as an identifier Adjustable range of mobile identifier when using Bluetooth Low power consumption Special encryption algorithm for mobile IDs and MIFARE Plus cards Ability to apply to any types of objects Ability to install UKEY Mobile access in previously aquired outdoor panels Convenience in use Working principle Identification and unlocking is possible due to the p...

Page 50: ...e from 0 5 meter to 10 meters Triple clicking setup with UKEY Cfg5 application Application abilities Adjusting operating mode of EM Marin cards MIFARE and BLE Bluetooth Low energy enable disable standards of reading Setting ecryption for UKEY identifier This will enable you to link the encrypted ID key to the selected reader Enable disable encrypting mode for MIFARE Classic and MIFARE Plus cards E...

Page 51: ...o be able to use TR 03B to issue mobile identifiers or to record access cards it is necessary to specify the master card which will be needed for the reader to work in the future The Master card is specified when the reader is first started Create a master card 1 Download and install UKEY Cfg mobile application 2 Connect TR 03B reader to the power source 5V USB 3 Launch UKEY Cfg app and press Sear...

Page 52: ... USB Reader Server 3 Connect the reader to PC 4 Bring a master card to the reader 5 Bring a cell phone to the reader make sure Bluetooth is on and enter UKEY App then press Obtain button or select Obtain BAS IP TR 03 key 6 The reader will transmit a mobile ID to your cell phone thus Your key is ready will appear in the app ...

Page 53: ... call panel to the video surveillance system you need to put in the add line of the camera rtsp admin 123456 192 168 1 16 8554 ch01 where admin is the login 123456 is the password to access the WEB interface 192 168 1 16 is the IP address of the panel 8554 is the port of access to the camera ch01 is the channel number ...

Reviews: