BAS-IP AA-07BD Quick Start Manual Download Page 4

Device Settings

In this menu, you can configure:

P

anel operation 

mode

• 

• 

Wall mode

 is used when the panel is installed on the perimeter of the object.

If this variant is chosen, on the panel you must enter 

Building No.

,

 Unit No.

,

 Floor No.

, and 

Apartment No.

to call the necessary monitor. 

Unit mode

 is required if the panel is installed near the unit entrance.

• 

When using this mode, it is enough to enter 

Floor No.

 and 

Apartment No.

 to call the necessary monitor.

• 

D

evice 

language

 (Russian, English, Ukrainian, Spanish, Polish, or Dutch)

• 

P

anel logical address (

Building No.

Unit No.

, and 

Device No.

For correct functioning, the panel and the monitor must have the same 

building

 and 

unit number

in apartment settings. Also for monitors, you must indicate corresponding information about the floor,
apartment, and device number.

If you have more than 1 entrance panel with the same logical address, you need to specify their

device numbers

, starting from 1 for the main device, and from 2 to 9 for others.

• 

A

dmin password to enter device settings and web interface

 

L

evel of panel speaker 

volume

• 

P

anel camera stream 

resolution

 (320x240 / 640х480 / 1280х720)

• 