Installation Instructions
20 / 70
117262
EN
Water Connection
• Make sure that the potable water connection is located close to the appliance.
• If new installation is carried out, before the appliance is connected to water
supply system, drain sufficient amount of water to prevent contamination of
magnetic valves.
• Fix the included water supply tube to
the appliance's connection element
(3/4"). The connection is located under
the appliance, to the right (Fig. 4).
• Connect the other end of the water
pressure tube to cold water installation
and install a closing valve and a filter
between them.
• Make sure that the closing valve is
installed in an easily accessible place
for the user.
Abb. 4
ATTENTION!
Hydraulic water pressure should be max. 3 bar.
If the water pressure in the installation is higher, install pressure reducer
upstream of the appliance.
The minimum water pressure should be exceeding 1.5 bar to assure correct
operation of the appliance.
In order for the appliance to operate properly and to avoid limescale deposits in the
thermal processing chamber, drinking water of hardness up to 5° dH (German
scale) must be available.
ATTENTION!
With water hardness exceeding 5° dH (German scale) a suitable water
softening device must be installed upstream of the appliance.
Summary of Contents for Silversteam-K 6110DRS
Page 1: ...Silversteam K 117262 117263 117264 117265...
Page 17: ...Technical Data 117262 15 70 EN 4 2 List of Components of the Appliance Fig 1...
Page 32: ...Operating Instruction 30 70 117262 EN Start screen Fig 8...
Page 44: ...Operating Instruction 42 70 117262 EN Saving Thermal Processing Program Fig 21...