Possible Malfunctions
105926
21 / 24
EN
7
Possible Malfunctions
Mögliche
The table below contains descriptions of possible causes and solutions to
malfunctions or errors during operation of the appliance. When malfunction cannot
be removed, contact the technical service.
Error code
Cause
Solution
E0
No cookware on a hob or
inappropriate cookware.
Use only suitable cookware.
E1
Appliance is getting too
hot (e.g. due to
obstructed ventilation
openings).
Open the passage through
ventilation openings. Leave the
appliance to cool down and restart.
If the error code is still shown in the
digital display, contact the service
company.
A damaged element (e.g.
a transistor).
Contact the service company.
E2
The overheating
protection has been
activated and the device
will switch off.
Disconnect the appliance from the
power supply (pull the mains plug
out). Remove cookware from a hob.
Leave the appliance to cool down,
and re-start.
E3
Short-lasting power cut.
Disconnect the appliance from mains
power supply. After a few minutes,
plug the appliance in again.
Have an electrician to check the
electrical connection.