GB
25
A Adjustementof the evaporator water level
The correct water level in the freezing cylinder is
about 25 mm. below the ice discharge opening.
Low water level causes excessive strain inside
the freezer assembly due to a faster freezing
rate.
When the water level is above or below the cor-
rect one, adjustment can be performed by rai-
sing or lowering at the measure required, the
water reservoir and its mounting bracket.
1 To Raise or Lower the water level:
a Loosen and remove the screw securing
the mounting bracket of the water reser-
voir to the unit cabinet and raise the water
reservoir to the correct level.
b Thread the mounting screw in the corre-
sponding hole and tighten it.
2 For the reduction the water level as given
above, and lower the bath, as soon as it is
released from the casing.
B. Replacement of the gearmotor magnetic
sensor
1 On F80, F120 remove the front/top and
side/rear panels top and left side panels.
2. Unloose the three screws securing the pla-
stic cover to the top of the gear motor and
remove it.
3. Unloose the two screws securing the magne-
tic sensor to the plastic housing and with-
draw it from its seat.
4. Trace the gear motor magnetic sensor termi-
nal plug on the rear side of the control box
(red with four terminal pins) and draw it out
from its socket by carefully slackening the
fastening tie.
5. To install the replacement gear motor magne-
tic sensor follow the above steps in reverse.
WARNING. Be sure the electrical power
supply circuit breaker and the inlet water
supply are OFF, before starting any of the
following Removal and Replacement pro-
cedures as a precaution to prevent possi-
ble personal injury or damage to the
equipments.
NOTE.
Read the instructions throughly befo-
re performing any of the following adjustment
or removal and replacement procedure.
ADJUSTMENT, REMOVAL
AND REPLACEMENT PROCEDURES
Summary of Contents for F 120
Page 2: ......