Installation Instructions
117910
19 / 68
EN
– an electrical connection with appropriate fuses and a main switch located
nearby
– a connection to the equipotential bonding system — separate earth cable
– a connection to cold water supply with softening system with valve and
pipe pressure of 2.5
–3.5 bar
– a condensate drain to drain with a trap
– a ventilation system and vapour extraction (condensation hood) above
the appliance.
• The appliance must be transported to the installation location in packaging, on
its dedicated wooden pallet.
• Transportation must be executed with the use of pallet trolley or forklift,
observing all safety precautions, in order to avoid the risk of tipping it over. Also,
following the operation period, the appliance must be transported on a pallet and
manipulate with the highest caution, in order to avoid the risk of tipping it over.
• Remove the external packaging (wooden crate and/or carton box) and utilize it
according to regulations in force in the country of installation.
CAUTION!
Choking hazard!
Prevent children from accessing packaging materials, for instance: plastic
bags and EPS elements.
• Check if the appliance is undamaged.
• Before positioning the appliance, check the dimensions and exact positions of
the electric, water, and extraction connections.
• If the appliance is covered with a protective film, remove it. Remove the film
slowly, so no glue residues are left. Remove any glue residues with the use of a
suitable solvent.
• Be careful not to damage the rating plate and warning labels affixed to the
appliance.
• Remove all accessories, information materials, and plastic bags from the
appliance.
• Check if ventilation openings and fume extractor are not covered nor obstructed
in any way.
• Place the appliance in a way making the connections easily accessible, so that
they may be quickly disconnected if such a need arises.