(Table 5) BURNER FEATURES (IS - CAT.
I
3P
)
Gas type
Nominal
Capacity
[kW]
Reduced
Capacity
[kW]
Main Injector
Diameter
[1/100 mm]
By-Pass
Diameter
[1/100 mm]
Position [N.]
Air Regulation
“x” [mm]
BAIN MARIE BURNER½ UNIT
Liquid Gases LPG
(G31)
4.00
1.10
1.00
0.45
16.2
3.0
BAIN MARIE BURNER 1 UNIT
Liquid Gases LPG
(G31)
6.00
2.50
1.25
0.75
16.2
-
(Table 6) BURNER FEATURES (LV - CAT.
I
2H
)
Gas type
Nominal
Capacity
[kW]
Reduced
Capacity
[kW]
Main Injector
Diameter
[1/100 mm]
By-Pass
Diameter
[1/100 mm]
Position [N.]
Air Regulation
“x” [mm]
BAIN MARIE BURNER½ UNIT
Natural Methane Gas
(G20)
4.00
1.10
1.55
0.80
27.2
5.0
BAIN MARIE BURNER 1 UNIT
Natural Methane Gas
(G20)
6.00
2.50
1.75
1.20
27.2
-
(Table 7) BURNER FEATURES (CZ,SK - CAT.
II
2H3B/P
)
Gas type
Nominal
Capacity
[kW]
Reduced
Capacity
[kW]
Main Injector
Diameter
[1/100 mm]
By-Pass
Diameter
[1/100 mm]
Position [N.]
Air Regulation
“x” [mm]
BAIN MARIE BURNER½ UNIT
Liquid Gases LPG
(G30-G31)
4.00
1.10
0.90
0.45
16.2
3.0
Natural Methane Gas
(G20)
4.00
1.10
1.55
0.80
27.2
5.0
BAIN MARIE BURNER 1 UNIT
Liquid Gases LPG
(G30-G31)
6.00
2.50
1.10
0.75
16.2
-
Natural Methane Gas
(G20)
6.00
2.50
1.75
1.20
27.2
-