In  order  to  replace  the  burner 
nozzle, remove the knobs (1) and 
the lifting crank (2); then remove 
the 

front 

panel 

(3) 

by 

unscrewing  the  4  screws  that 
hold it in its place (4). Unscrew 
the connection (5) that joins the 
ramp (6) to the electro-valve (7) 
and  the  screws  (8)  that  fix  the 
electro-valve  to  the  appliance 
frame.  After  clearing  the  work 
area,  loosen  the  screw  (9)  that 
blocks 

the 

primary 

air 

regulation, close the clamp wide (10); unscrew the nozzle (11) with a spanner and replace it with an 
appropriate nozzle for the gas type to be used. Reassemble the nozzle, tightening it well and proceed 
with regulating the primary air, as indicated in the next paragraph. When all this is done, put back the 
parts previously removed. 

Regulating the primary air of the burner

  

After substituting the burner nozzle, the primary air must be regulated. Therefore, loosen the screw 
(9) that fixes the bush (10); bring value “

X

” to the correct measurement; tighten the screw (4) and 

check the accuracy of value “

X

”. 

Substituting the pilot burner nozzle

 

In  order  to  replace  the  nozzle  of  the  pilot 
burner, remove the knobs (1) and the lifting 
crank (2); then remove the front panel (3) by 
unscrewing  the  4  screws  that  hold  it  in  its 
place  (4).  Unscrew  the  connection  (5)  that 
joins  the  ramp  (6)  to  the  electro-valve  (7) 
and the screws (8) that fix the electro-valve 
to the appliance frame, as shown in picture 
13. Unscrew the fitting (12) which fixes the 
gas supply pipe of the pilot (13) and remove 
the nozzle (14). Substitute it with the nozzle suitable for the gas type to be used. Then proceed to 
reassemble the new nozzle, reposition the pipe and tighten the fitting fully. When all this has been 
done, put back the parts previously removed.

 

 

 

Summary of Contents for 2856031

Page 1: ...INSTALLATION USE AND MAINTENANCE Gas Bratt Pans Serie 700 2856031 2856811 ...

Page 2: ...te Table of gas types p 2 General Warnings p 19 Normes et Directives p 19 Installation and Gas Electric connection p 20 General Warnings for the Maintenance p 24 Gas Bratt Pans p 180 199 Cooking equipment Series 700 ...

Page 3: ...in mbar PMAX mbar G20 Methane 2H 20 17 25 G25 Methane 2ELL 20 17 25 G25 Methane 2E 25 20 30 G25 1 Methane 2HS 25 20 30 G25 3 Methane 2EK 25 20 30 G30 Butane 3B P 28 30 25 35 G30 Butane 3 28 30 20 35 G30 Butane 3B P 50 42 5 57 5 G31 Propane 3B P 28 30 25 35 G31 Propane 3P 3 37 25 45 G31 Propane 3B P 50 42 5 57 5 G110 Town gas 1a 8 6 15 G120 Town gas 1ab 8 6 15 ...

Page 4: ...ot be obstructed Children should be supervised to ensure they do not play with the appliance Before connecting the device make sure that the plate specifications correspond to the electrical and gas supply When cooking avoid placing pots and pans and or crockery on the hotplate that could partially cover the stainless steel part of the hob otherwise the worktop may overheat When not in use make su...

Page 5: ...ces for home professional use and industry SVGW Regulation of cantonal applications in Switzerland for ex fireproof regulations And the particular reference norms Declaration of compliance The manufacturer declares that the appliances of their production meet the above mentioned EEC directives and requires that installation be done observing the norms in force particularly regarding the system for...

Page 6: ...umes evacuation Type A1 gas appliances The deep fat fryers are type A1 gas appliances and it is not necessary to connect directly to an evacuation pipe for combustion products The products of combustion however have to be directed into suitable hoods or similar devices connected to a reliably efficient chimney otherwise directly outside if these devices are not available it is possible to use an e...

Page 7: ...egs Gas Connection Before connecting the appliance it is necessary to check that the type of gas available corresponds to the type of gas the appliance has been set for In the event that they do not correspond it is necessary to proceed as described in the paragraph Functioning with a gas type different from the type provided for The connection to the screwed pipe joints which have a diameter of i...

Page 8: ...only a single appliance to each switch In some cases after long periods of inactivity or in case of a new installation it is possible that the appliance switches off during the setting up The main reason is usually the moist produced during the isolation The problem can be easily solved through a short pre heating bypassing the safety thermostat FOR PASTA COOKERS ONLY Connection to the water mains...

Page 9: ...s supply company The reading has to be done when the appliance is already in function Checking pilot burner Check the flame of the pilot burner which must be neither too short nor too high but must lap the thermocouple and have a sharp form otherwise it is necessary to check the size of the nozzle depending on the pilot version as specified in the following paragraphs Checking regulation of primar...

Page 10: ... B appliances following the prescriptions in force in the country of installation The gas tap should be lubricated but this operation is quite difficult and its results are not very reliable Therefore it is advisable to substitute the gas tap ...

Page 11: ...eatures p 181 Burners Features p 182 Dimensions p 185 Description of appliances p 199 Regulation using a different type of gas p 199 Substituting components p 201 Operating anomalies p 201 Instructions for Use p 202 Device care and cleaning p 203 ...

Page 12: ...t Capacité cuve Tank capacity l 52 5 52 5 Gas Gaz B KW 12 5 12 5 Typ Type Typ A A1 A1 GPL LPG G30 D Kg h 0 986 0 986 Erdgas Methane G20 C m3 h 1 322 1 322 Luft Air m3 h 25 38 Gasanschluss Racc Gaz Gas fitting UNI ISO 7 1 R UNI ISO 7 1 R Elektr Electr E KW 0 0055 0 1555 F Volts 230 1 230 3 G Hz 50 50 Kabel Cable H07 RN F mm2 3x1 3x1 Wassedruck Pression eau Water pressure MAX kPa 300 300 Wasseransch...

Page 13: ...amme Piloto N Aria Air Luft Aire x mm BRUCIATORE BRÛLEUR BURNER BRENNER QUEMADOR Liquid Gas PLG 12 50 AL125 x 2 16 2 1 5 G31 Tabella Tableau Table Tafel Tabla 77 CY MT HU NL CAT I3B P 29mbar Tipo gas Type gaz Gas Type Gasart MAX kW MIN kW Ø Ugello Gicleur Injector Düse Inyector 1 100 mm Ø By pass 1 100 mm Pilota Veilleu se Pilot Zündf lamme Piloto N Aria Air Luft Aire x mm BRUCIATORE BRÛLEUR BURNE...

Page 14: ...UEMADOR Natural Methan gas 12 50 AL190 x 2 27 2 0 5 G20 Liquid gas LPG 12 50 AL125 x 2 16 2 1 5 G30 G31 Tabella Tableau Table Tafel Tabla 81 CH SK DE AT CAT ΙΙ2H3B P 50 mbar Tipo gas Type gaz Gas Type Gasart MAX kW MIN kW Ø Ugello Gicleur Injector Düse Inyector 1 100 mm Ø By pass 1 100 mm Pilota Veilleu se Pilot Zünd flamme Piloto N Aria Air L uft Aire x mm BRUCIATORE BRÛLEUR BURNER BRENNER QUEMAD...

Page 15: ...n gas 12 50 AL190 x 2 27 2 0 5 G20 Natural Methan gas 12 50 AL210 x 2 27 2 0 5 G25 Liquid gas LPG 12 50 AL105R x 2 16 2 1 5 G30 G31 Tabella Tableau Table Tafel Tabla 85 NL CAT II2EK3B P Tipo gas Type gaz Gas Type Gasart MAX kW MIN kW Ø Ugello Gicleur Injector Düse Inyector 1 100 mm Ø By pass 1 100 mm Pilota Veilleu se Pilot Zünd flamme Piloto N Aria Air Luft Aire x mm BRUCIATORE BRÛLEUR BURNER BRE...

Page 16: ...Piloto N Aria Air Luf t Aire x mm BRUCIATORE BRÛLEUR BURNER BRENNER QUEMADOR module Natural Methane Gas 12 50 AL190 x 2 27 2 0 5 G20 Liquid Gas LPG 12 50 AL125 x 2 16 2 1 5 G30 G31 Town Gas 11 80 AL380 x 2 45 2 0 G110 Town Gas 12 80 AL380 x 2 45 2 0 G120 DIMENSIONS DIMENSIONS RAUMBEDARFMASSE 12 5 kW 2856811 2856031 G gas gaz ϕ1 2 E électrique electric elektrisch C Remplissage d eau Water filling W...

Page 17: ...ange to another gas type it is necessary to substitute the nozzles of the main burners and of the pilot burner following the instructions in the following paragraphs The nozzle type to be installed can be found in tables BURNER FEATURES The nozzles of the main burner marked with their diameter in hundredths and the nozzles of the pilot burner marked with a number are to be found in a transparent p...

Page 18: ... air of the burner After substituting the burner nozzle the primary air must be regulated Therefore loosen the screw 9 that fixes the bush 10 bring value X to the correct measurement tighten the screw 4 and check the accuracy of value X Substituting the pilot burner nozzle In order to replace the nozzle of the pilot burner remove the knobs 1 and the lifting crank 2 then remove the front panel 3 by...

Page 19: ...nstall everything following the inverse sequence For better sealing it is advisable to screw the connections 9 to the valve by interposing a clamping screw Thermocouple In order to replace the safety valve remove the water and gas knobs and the crank then remove the front panel by unscrewing the four screws that hold it in its place Then unscrew the fitting of the thermocouple on the cock and the ...

Page 20: ... power supply Check the condition of the heating element Check the thermostat No indicator light Check the power supply Check the light bulb Slow and or inadequate heating Check the setting of the thermostat Check the condition of the heating elements Check the quantity of food to be cooked INSTRUCTIONS FOR USE The braising pan is universal equipment it is suitable for roasting cooking and grillin...

Page 21: ... operation must always be carried out under surveillance If the lid is kept closed during cooking be careful when you lift it there is a risk to get burnt due to the steam produced inside the cooking vat CARE AND MAINTENANCE OF THE APPLIANCE Cleaning ATTENTION Before doing any cleaning make sure that the appliance is disconnected from the electric mains and that the gas cut off valve is closed Dur...

Page 22: ...e for a long time it is advisable to turn off the gas tap Then disconnect the main electricity supply wipe all stainless steel surfaces with a cloth soaked in Vaseline oil in order to give it a protective film air the rooms now and again ATTENTION Never use substances detergents and other solutions containing chlorine or its by products In order to remove any possible scale marks do not use produc...

Reviews: