- 45 -
5.2.2 Device switch on/off
WARNING! Risk of burns!
During the flame ignition, never lean over the device.
High flames from this area my lead to severe burns.
Pilot flame ignition (Fig. 7)
•
Press the burner knob and turn left to MAX position (
C
), hold the knob pressed
and ignite the pilot flame with a match. Hold the burner knob pressed for a few
more seconds to allow heating up of the thermocouple. If the pilot flame goes
out, repeat the process.
Main burner ignition (Fig. 7)
•
To ignite the main burner, turn the burner knob left to MAX position (
C
)
or further, until the lowest MIN position (
D
).
•
Heat output may be adjusted between these two settings.
Switching off (Fig. 7)
•
In order to switch the main burner off, turn the burner knob right to position (
B
), thus
leaving only a control valve switched on. Turn the burner knob to position (
A
), to
switch the pilot flame off.