background image

Pag.  9

The appliance must be positioned in a location that ensures adequate evacuation of the combustion products 

in compliance with national installation standards and the installation place must be appropriate to the type of 

appliance. Our appliances are type A

1

. This means that no fume flue or exhaust device can be installed outside 

the room in which the appliance is installed. The combustion air is taken from and the combustion products are 

discharged into the room in which the appliance has been installed.  

The appliance should nevertheless be installed underneath an extraction hood or device of similar efficiency in 

the manner prescribed by current national standards.

1.3  EVACUATION OF EXHAUST FUMES

1.2 POSITIONING

Remove the appliance from the packing, check it 

for damage and place it in the installation position. 

Level it and adjust its height by using the levelling 

feet indicated in (Fig. 1).  The appliance must be 

kept at least 10 cm away from flammable walls. 

The bain marie may be placed against refractory 

and non-combustible walls. 

Do not obstruct the aspiration or heat di-

scharge openings and gaps and place the 

appliance underneath an extraction hood that 

complies with current standards.  

Fig. 1

1.4  CONNECTING GAS

INSTALLATION INSTRUCTIONS

Installation operations, adaptations to other types of gas, commissioning and the elimination of system faults must 

be carried out only by qualified personnel in accordance with current rules and standards. The gas systems, wiring 

and premises in which the appliances are installed must comply with current rules and standards. In particular, 

the air supply for burner combustion must be 2 m

3

/h per kW of installed nominal power.

Accident prevention, fire prevention and anti-panic measures in businesses open to the public must be complied 

with.

CHECK BEFORE INSTALLATION

The appliance has a rating plate (Fig.2) and the installation instructions are given in the main European languages. 

The packing also displays an additional rating plate showing the values for which the appliance is rated and the 

country of destination.  

Fig. 2

Summary of Contents for 131.1413

Page 1: ...N AND MAINTENANCE MANUAL FOR GAS FRY TOPS MANUEL D INSTRUCTIONS POUR L UTILISATION ET L ENTRETIEN DES FRY TOPS GAZ GEBRAUCHS UND WARTUNGSANLEITUNG FÜR GAS FRY TOPS MANUAL DE INSTRUCCIONES PARA EL USO Y EL MANTENIMIENTO DEL FRY TOP GAS REV 04 2012 COD ZSL6508 131 1413 131 1813 ...

Page 2: ...n be consulted by different users If the appliance changes owner the user manual must also be transferred to the new owner if necessary request a new copy from the authorised dealer or directly from the manufacturer Only qualified persons must be entrusted with installation operations adapting the appliance to different types of gas commissioning and eliminating system faults All current rules and...

Page 3: ...t 10 cm away from flammable walls The bain marie may be placed against refractory and non combustible walls Do not obstruct the aspiration or heat di scharge openings and gaps and place the appliance underneath an extraction hood that complies with current standards Fig 1 1 4 CONNECTING GAS INSTALLATION INSTRUCTIONS Installation operations adaptations to other types of gas commissioning and the el...

Page 4: ...juster in order to ensure optimum operation CHECKING THERMAL POWER During initial installation and during maintenance or adaptation to another type of gas nominal heat input must be measured It can be measured by using the volumetric method with the aid of a litre counter or a chronometer After checking connecting pressure and the diameter of the injectors which must be stamped on the injector mea...

Page 5: ... operates correctly instruct the user on how to use it Fig 5 1 5 CONNECTING TO A DIFFERENT TYPE OF GAS REPLACING MAIN BURNER NOZZLE Fig 4 1 Burner 2 Nozzle Before adapting to a new type of gas shut off the gas cock upstream Loosen the screws that hold the front control panel in place and disconnect the electric cables of the piezoelectric ignition Loosen the main injectors Ref 2 and repla ce them ...

Page 6: ...king day switch off the gas check valve upstream of the appliance The control knobs of the burner taps have two positions shut lighting pilot light The appliance must be used only for the purpose for which it was designed Any other use is improper During operation supervise the appliance 2 1 STARTING UP FOR THE FIRST TIME Before starting up the appliance for the first time remove all the packing a...

Page 7: ...arm soapy water on steel surfaces and then rinse in plenty of water and dry with a soft cloth Maintain the shine by regular polishing with a normal liquid polish Do not wash the work top or floor with hydrochloric acid PLATE In order to remove any encrusted residue scrape with a hard plastic spatula positioned at an angle Clean the plate regularly using a damp cloth After cleaning switch the plate...