background image

 

 

 

- 26 - 

Digital temperature regulator 

 

Display and functions 

  

Primary temperature settings are established at the factory and correspond to a working 
temperature in the device of approx. 0 °C - 10 °C.   

During normal use, the display will show the temperature as measured by the sensor.   
The LED will also show the current state of functions (table 1), and by using the 3 buttons 
some functions can be activated/deactivated (table 2). 

 

 

Tab. 1 

 

LED 

Function 

Normal working mode 

Start 

ON 

OFF 

Flashing 

 

 

 

Compressor  On 

Off 

Needed 

ON 

 

 

Ventilator 

On 

Off 

Needed 

ON 

 

 

Defrost 

On 

Off 

Needed 

ON 

 

 

Aux  

Device is on 

Device is off 

ON 

 

 

Time 

RTC function 
is available 
and/or active 
and set for at 
least 1 time 
period 

RTC function is 
not available or 
turned off, or no 
time period has 
been set  

ON, if the 
RTC 
function 
is 
available  

 

 

Alarm  

All 

No alarm 

ON 

 

 

Digital 
display 

Composed of 3 lighted values with comma/period and 
range of -199…999. See parameters /4, /5, /6 for the 
display of values detected by sensor, values in °C/ °F and 
after the comma/period 

 
 
 
 

Summary of Contents for 110.709

Page 1: ...110 709 110 710 V2 0712 ...

Page 2: ...nd storage 22 3 1 Delivery check 22 3 2 Packaging 22 3 3 Storage 22 4 Technical data 23 4 1 Overview of parts 23 4 2 Technical specification 24 5 Installation and operation 24 5 1 Safety instructions 24 5 2 Installation and connection 25 5 3 Operating 25 29 6 Cleaning and maintenance 29 6 1 Safety advice 29 6 2 Cleaning 29 6 3 Safety instructions for maintenance 30 7 Possible Malfunctions 31 8 Was...

Page 3: ... servicing maintenance or cleaning 1 2 Key to symbols In this manual symbols are used to highlight important safety instructions and any advice relating to the device The instructions should be followed very carefully to avoid any risk of accident personal injury or material damage WARNING This symbol highlights hazards which could lead to injury Please follow the instructions very carefully and p...

Page 4: ...not following the instructions for use The instruction manual should be kept near the device easily accessible for anyone wishing to work with or using it We reserve the right to make technical changes for purposes of developing and improving the useful properties 1 4 Copyright protection The instruction manual including any texts drawings images or other illustrations is copyright No part of this...

Page 5: ...t hazards and to ensure optimum efficiency no modifications or alterations to the device that are not explicitly approved by the manufacturer may be undertaken This device may only be operated in technically proper and safe condition 2 2 Safety instructions for use of the device The specifications regarding the industrial safety are based on the Regulations of the European Union applicable at the ...

Page 6: ...e is intended for commercial use only and should be operated by qualified personnel in professional food service organizations Safe operation is only guaranteed when using the device for its intended purpose Any technical interventions as well as assembly and maintenance are to be made by a qualified customer service only The cooled table is intended only for preparing and cooling appropriate food...

Page 7: ...r The outer and inner packing material should be removed completely from the device before installation NOTE If you liked to dispose the packing consider the regulations applicable in your country Supply re usable packing materials to the recycling Please inspect the device upon completeness In case any part is missing please contact our customer service center immediately 3 3 Storage Keep the pac...

Page 8: ... 23 4 Technical data 4 1 Overview of parts Housing Marble countertop ON OFF switch with integrated control light Ventilation ducts Digital temperature regulator Door Drawer Adjustable legs ...

Page 9: ... parts See that the cable does not touch any heat sources or sharp edges Do not let the cable dangle over the counter edge Do not use the device in case it does not function properly has been damaged or dropped Do not use any accessory or spare parts that have not been recommended by the manufacturer These can be dangerous for the user or lead to damages of the device or personal injury and furthe...

Page 10: ... cover the device s ventilation ducts Do not place the device where high levels of ambient humidity occur Such high humidity may damage the device The electrical circuit in the socket must be secured to at least 16A Only connect the device directly to the wall socket do not use any extension cords or power strips Place the device so that the plug is easily accessible and can be quickly removed fro...

Page 11: ...ctivated table 2 Tab 1 LED Function Normal working mode Start ON OFF Flashing Compressor On Off Needed ON Ventilator On Off Needed ON Defrost On Off Needed ON Aux Device is on Device is off ON Time RTC function is available and or active and set for at least 1 time period RTC function is not available or turned off or no time period has been set ON if the RTC function is available Alarm All No ala...

Page 12: ...ssed together RESET of paramaters activated 1 sec Programmin g version displayed Down Defrost Set mute 1 sec display setting of longer than 3 sec access to paramater configuration menu enter code 22 Deactivates signal buzzer 1 sec reset current EZY settings Setting desired values required temperature To regulate and change desired values Press for one second the set value will begin flashing incre...

Page 13: ...ormed by qualified service personnel Tips for the user The cooled table should be filled when it reaches the desired temperature which will be readable on the display Never place warm food products liquids or uncovered food products inside the refrigerated cabinet Use hermitically sealable containers for storing food products and beverages to prevent mixing of aromas inside the cooled table When f...

Page 14: ...washing via water jets Therefore you must not use any kind of pressure water jet for cleaning the device 6 2 Cleaning o Clean the table regularly o Disconnect the device from its power source by removing the plug o Clean the shelves and drawers with an appropriate disinfecting agent o Clean the unit s marble countertop and housing with a moist soft cloth Dry the unit thoroughly o Never use harsh c...

Page 15: ... and accessories should carry out repairs and maintenance of the device Do not attempt to repair the device yourself Maintenance So that the cooling device will function properly for a long period of time perform the following maintenance work on the condensator regularly o remove the device s plug from its socket o open the cooling device to get access to the condensator WARNING Danger of burns T...

Page 16: ...Products placed inside the device are too hot Cooled table is overfilled Ensure proper distance between cooled table and heat source Ensure proper distance from walls and other objects Allow products to cool before placing them inside the cooled table Do not overfill the cooled table remove unneeded food products if possible The above situations are only examples designed to assist you in determin...

Page 17: ...sposal service in your community WARNING To exclude any abuse and the dangers involved make the waste device unfit for use before disposal For that purpose disconnect device from mains supply and remove mains connection cable from the device NOTE For the disposal of the device please consider and act according to the national and local rules and regulations Bartscher GmbH Franz Kleine Str 28 D 331...

Reviews: