Possible Malfunctions
104304
21 / 30
EN
Water Inlet Filter
The water inlet filter must be regularly cleaned, observing the blow indications:
– close the water shut-off valve;
– unscrew water supply tube;
– use tweezers to pull the water inlet filter from the socket at the inlet of the
solenoid valve;
– clean the water inlet filter under running water;
– fit the water inlet filter;
– fit water supply tube.
7
Possible Malfunctions
Mögliche
ATTENTION!
The table below contains descriptions of possible causes and solutions to
malfunctions or errors during operation of the appliance. These
malfunctions may be cleared by a qualified refrigeration technician.
In such a case, provide article number, model name and serial number. These data
may be found in the rating plate.
Malfunction
Alarm
Appliance Condition
Solution
Too long a cooling
cycle alarm
Check condenser for ventilation
Check the cooling circuit for loss
of coolant
Change in duration
of alarm between
two production
cycles
Duration of alarm
between two production
cycles changed
Check condenser for cleanliness
and ventilation
Check condenser's fan
Check the circulation for loss of
the coolant