background image

7

Network Connection

This apparatus is suitable for connection for direct 2 wire connection to the
PSTN and indirect 2 wire connection to the PSTN via compatible extensions
on a PABX system.

Facilities

The WC21 Controller's modem has been approved for use with the following
facilities:
• Signalling to the PSTN using DTMF signalling only
• Auto-answering
• Auto-call clearing
• Data modem

The modem should be set up for blind dialling (e.g., dial after delay, no dial tone
detection).

Any other usage will invalidate the approval of the apparatus if as a result it
then ceases to conform with the standards against which approval was gained.

Connection Methods

This apparatus is designed for connection to the PSTN using a modular jack
connection (RJ 11).
Connection to national networks in the EU may require an adapter compatible
with the national network.

CTR21 Type Approval
Annex II - Type Approval

The equipment has been approved in accordance with Council Decision 98/
482/EC for paneuropean single terminal connection to the Public Switched Tele-
phone Network (PSTN). However, due to differences between the individual PSTNs
provided in different countries, the approval does not, of itself, give an uncondi-
tional assurance of successful operation on every PSTN network termination
point.
In the event of problems, you should contact your equipment supplier in the
first instance.

Annex III - Network Compatibility Declaration

We, Barton Instrument Systems of 900 South Turnbull Canyon Road, City of
Industry, CA91749, USA, declare under our sole responsibility that the WC20
Controller's internal modem is designed to interwork with the following networks:
Austria, Belgium, Denmark, Finland, France, Germany, Greece, Iceland, Ireland,
Italy, Liechtenstein, Luxembourg, Netherlands, Norway, Portugal, Spain, Swe-
den, Switzerland, United Kingdom.
and that there may be interworking problems with the following networks:
Germany, Greece, Portugal, Spain.
The network compatibility is not dependent on physical or software switch
settings.
If you wish to use this equipment on another network, please contact your
equipment supplier.

EU CTR21 STATEMENT FOR WC21

Summary of Contents for TankScan W-Series

Page 1: ...ntroller on stable flat surface or mount on wall a If desired install the self adhesive rubber feet b To wall mount attach mounting plate to bottom of enclosure using supplied screws then attach the a...

Page 2: ...ation process US Power Adapter EU Power Adapter l e b a L e m a N n o i t p i r c s e D R W P r e w o P n o s i t i n U H O k o o H f f O k o o h f f o e n i l e n o h P X T a t a D t i m s n a r T a...

Page 3: ...0 Ohm transformer coupled CTR21 complex impedance Dial Type DTMF or Pulse subject to national approvals Baud Rate 2400 CCITT V 22bis 1200 CCITT V 22 or Bell 212A Note This modem will not detect cadenc...

Page 4: ...List Part Description Part Number AC Power Adapter US TL10 2009T Antenna standard TL10 2004T Optional Outdoor Antenna with mount 20 ft cable WC20 2046B 1 30 ft cable WC20 2046B 2 Telephone Cable 10 T...

Page 5: ...party lines is subject to state tariffs There are no user serviceable parts in this modem If there is a problem or the modem needs to be repaired or serviced return it to the company where it was orig...

Page 6: ...connect the equipment For your own protection make sure that the electrical ground connections of the power utility telephone lines and internal metallic water pipe system if present are connected tog...

Page 7: ...98 482 EC for paneuropean single terminal connection to the Public Switched Tele phone Network PSTN However due to differences between the individual PSTNs provided in different countries the approval...

Page 8: ...X X X O I D A R z H M 8 2 9 2 0 9 a c i r e m A h t r o N 0 z H M 0 7 8 7 9 6 8 e p o r u E 1 M E D O M l a n r e t n I n a c i r e m A h t r o N A 1 2 R T C l a n r e t n I n a e p o r u E C n o i t...