PARTS LIST

5

6

• Young children should be carefully supervised when they are in the area of the appliance at all times.

• Children should never operate this unit. Children must be supervised while near this unit.

• Clothing or other flammable materials should not be hung from the appliance, or placed on or near the appliance.

• Any guard or other protective device removed for servicing the appliance must be replaced prior to operating the appliance.

Installation and repair should be done by a qualified service person. The appliance should be inspected before use and at 

least annually by a qualified service person. More frequent cleaning may be required as necessary. It is imperative that the 

control compartment,burners and circulating air passageways of the appliance be kept clean.

• Installation and repair should be done by a qualified service person.Appliance should be inspected before use and inspected 

and cleaned by a qualified service person regularly.

• Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and 

any gas control which has been under water.

• Use only the specific size and capacity of the cylinder noted.

• A statement that the LP-gas supply cylinder to be used must be constructed and marked in accordance with the specifications 

for LP- gas

cylinders of the U.S. Department of Transportation (DOT).

• This appliance shall be used only outdoors in a well-ventilated space and shall not be used in a building, garage or any other 

enclosed area as the instructions state.

• Installation and repair should be done.

• How to disconnect a gas bottle?

Turn OFF control knob and LP cylinder valve.Turn coupling nut counterclockwise by hand only - do not use tools to disconnect. 

Loosen cylinder screw beneath bottom shelf, then lift LP cylinder up and out of shelf. Place dust cap on cylinder valve outlet 

whenever the cylinder is not in use.

• Storage of an appliance indoors is permissible only if the cylinder is disconnected and removed from the appliance. Cylinder 

must be stored outdoors in a well-ventilated area out of reach of children. Disconnected cylinders must have threaded valve 

plugs tightly installed and must not be stored in a building, garage or any other enclosed area.

WARNING

: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. 

Refer to the owner’s information manual provided with this appliance. For assistance or additional information consult a 

qualified installer, service agency or the gas supplier.

• The LP-gas supply cylinder must be disconnected when this appliance is not in use

• Only cylinder marked “propane” shall be used.

Caution

: Only use the pressure regulator and hose assembly supplied with this fire bowl. Replacement pressure regulator 

and hose assemblies must be specified. Inspect the hose before each use of the appliance. If the hose shows signs of cracks, 

abrasions, cuts or damage of any kind, do not operate the

appliance. Fix or replace the hose as required before using the appliance. Use only replacement parts from the manufacturer.

Allow heating item to cool completely before placing on lid. DO NOT use heating item/cover while the lid is installed. Always 

remove the lid while heating item in use. 

SAVE THESE WARNINGS.

Summary of Contents for 94131

Page 1: ...THIS MANUAL FOR SAFETY WARNINGS PRECAUTIONS ASSEMBLY OPERATION INSPECTION MAINTENANCE AND CLEANING PROCEDURES WRITE THE PRODUCT S SERIAL NUMBER ON THE BACK OF THE MANUAL OR THE MONTH AND YEAR OF PURCHASE IF PRODUCT HAS NO SERIAL NUMBER FOR QUESTIONS PLEASE CALL CUSTOMER SERVICE 909 628 4900 ...

Page 2: ...rating the product 1 The installation of this appliance must conform to local codes or in the absence of local codes to the Natiomal Fuel Gas Code ANS Z223 1 This manual contains important information about the assembly operation and maitenance of the fire pit General safety information is presented in these few pages and is also located throughout this manual Keep this manual for future reference...

Page 3: ...SAFETY INFORMATION 2 ...

Page 4: ...wl Do not pour water into fire bowl The installation of this product must conform with local codes or in the absence of local codes with either the National Fuel Gas Code ANSI Z223 1 NFPA54 OR CAN CGA B149 1 National Gas and Propane Installation Code Do not use this fire bowl if any part has been under water Do not store a spare or disconnected propane cylinder under or near this fire bowl After a...

Page 5: ...ng the valve or burner Cylinder supply system must be arranged for vapor withdrawal Propane Tank used must include a collar to protect the cylinder valve Never fill the cylinder beyond 80 full Propane gas is not natural gas Only use propane for this fire bowl The conversion or attempted use of natural gas in a propane unit or propane gas in a natural gas unit is dangerous Do not use this fire bowl...

Page 6: ...te Installation and repair should be done How to disconnect a gas bottle Turn OFF control knob and LP cylinder valve Turn coupling nut counterclockwise by hand only do not use tools to disconnect Loosen cylinder screw beneath bottom shelf then lift LP cylinder up and out of shelf Place dust cap on cylinder valve outlet whenever the cylinder is not in use Storage of an appliance indoors is permissi...

Page 7: ...PARTS INFORMATION 6 ...

Page 8: ...sure the tank sits on the metal seat completely Turn the wing screw on the out part of metal seat clockwise to secure the tank tightly see Figure D 7 Locate the battery remove the plastic cover the first Unscrew the rubber cap of the Electric ignitor place a AAA battery into battery case Make sure the positive pole towards the cap Screw the cap back to the battery case tightly see Figure E 8 Take ...

Page 9: ... off position See below figure A 2 Remove door and slowly open the valve on the propane gas tank by turning the knob counterclockwise 3 Replace the door on the body 4 Push and hold in the electronic igniter to create sparks within the electrode continue to hold 5 Push in the control knob and turn to the low position see figure below B Keep holding down the control knob to allow gas to flow for 15 ...

Page 10: ... but it does require proper maintenance to ensure the integrity of the surface Please see below for recommendations on maintaining your unit surface Clean any spills immediately to prevent permanent surface staining or damage Absorb any liquid spills with a clean dry cloth to avoid spreading of the spill to the rest of the table Clean surface with a soft clean cloth or sponge Mix a solution of war...

Page 11: ...MANUFACTURER AND OR DISTRIBUTOR EXPRESSLY STATES THAT ALL REPAIRS AND PARTS REPLACEMENTS SHOULD BE UNDERTAKEN BY CERTIFIED AND LICENSED TECHNICIANS AND NOT BY THE BUYER THE BUYER ASSUMES ALL RISK AND LIABILITY ARISING OUT OF HIS OR HER REPAIRS TO THE ORIGINAL PRODUCT OR REPLACEMENT PARTS THERETO OR ARISING OUT OF HIS OR HER INSTALLATION OF REPLACEMENT PARTS THERETO Record Product s Serial Number H...