Chromoflex - Manual - English V1.5
Rev. 03.05.2010
-5-
Subject due to technical changes
DIP-Switches
The selected Network and the Master mode are set with a small 4-DIP switch inside of the module.
The top of the cover can be easily removed.
Important: Please do not touch any of the electronic components, because of the risk of damage by
electrostatic discharge. We recommend using a small non-conductive tool to change the DIP
switches.
Important: Any change of the DIP switches become active after a reset or power on only !
Technical Data:
Operating Voltage: 7 - 26 Volt (+ 5%), stabilised.
Important: The power supply used must be able to bear pulsed loads. Unstabilised or too weak power
supplies can cause unwanted flickering effects, especially during colour changes!
Module current (without LED lamps): ca. 20 mA
Operating temperature: 0°C - max. +50°C (recommended: <= 30°C) (Use only in dry places with
sufficient air ventilation)
Modulation system: The Chromoflex modules are based on a digital System, called „Vector-Fractal-
Modulation“ or „VFM“. This modulation system was optimised for minimising load on power supplies
and has considerable advantages compared to traditional systems. The modulation frequency is in
the range from 120 Hz up to (max.) 240 Hz. Patent pending.
´
ChromoFlex RC CW`:
Pulsed constant voltage, maximum current 5 Ampere per channel (2 channels).
Contact / Internet:
Download of PC-Software, data sheets , technical support:
Contact (technical support by Internet / Email only!):
Manufacturing, Distribution and Sales: