2. Delivery / Scope of delivery

After receipt of the goods please check whether the delivery is complete and whether the items are intact. 
The delivery consists of one reel AQUALUC including a connection cable.

3. Area of application

Examples for applications of the AQUALUC:

• accent illumination 

• illumination for outdoor, wellness, spa and pool areas 

• architectural illumination 

• backlight for illumination of letters 

• shipbuilding 

• exhibition lighting 

• stairway illumination 

• illumination for bars, and many more

4. Technical data [extract]

5. Installation and commissioning 
5.1 Installation and processing guidelines

•  The 

processing temperature

 range of the AQUALUC is between 15°C and 35°C. Temperatures below 

this can negatively influence the flexibility of the stripe and can result in damage. If the AQUALUC was 
previously exposed to lower or higher temperatures, then it must be 

slowly

 brought into the processing 

temperature range.

•  Please note that the AQUALUC can marginally expand or contract with 

changes in temperature

 at the 

installation location. This is not a defect in the product but a normal physical process. Specifically, this 
means that there is a linear thermal 

expansion

 of approx. 1 mm per meter and 15 °C change in tempe-

rature. This extra expansion gap should always be taken into consideration prior to installation.

•  To avoid damaging the AQUALUC, especially during 

unrolling

 or 

mounting

, it is important that 

two people

 

install the product. This is especially valid for a length of one meter (1 m) or more. Care should be taken 
that the product does not sag otherwise irrevocable damage can occur (see illustration 1). Furthermore, 
the encapsulation of the product may not be damaged otherwise a sufficient protection of the LED stripe 
cannot be ensured. 

It is important to never exceed the minimum bending radius!

•  The 

minimum bending radius

 of the AQUALUC is 5 cm (ATTENTION: the minimum bending radius for 

AQUALUC 25 HP is 9 cm!). The minimum bending radius may not be exceeded and the stripe may not be 
bent, otherwise the AQUALUC could be damaged (see illustration 2). 

•  The product is suitable for 

installation

 on the floor, wall or ceiling - indoors and outdoors. Make sure that the 

product is mounted on a clean, flat and stable surface.

•  Depending on the surface and the application, the installation can be performed with the 

retaining bracket

 

(Art. 40100100), with thermal conductive double-sided 

adhesive tape

 (Art. 30033009) or with 

construction 

adhesive

 (Art. 63500030).

Detailed technical information can be found in the relevant data sheet at 

www.barthelme.de 

AQUALUC

 

14

AQUALUC

 

25

AQUALUC

 

25 HP

AQUALUC

 

33

24 V DC

operating voltage

Outdoor IP67/68

protection class

24 W | 12 W

26 W | 13 W

64 W

48 W | 24 W

typical power

2,700 K | 3,200 K | 4,600 K | 6,500 K 3,500 K | 4,400 K | 6,400 K | 9,000 K

RGB

colour temperatures

14 mm

25 mm

25 mm

33 mm

LED pitch

13.5 x 6 mm

dimensions  
width x height

Summary of Contents for AQUALUC

Page 1: ...eit und Abrieb resistent Der hohe Kup feranteil in den Leiterbahnen die Stromkonstanter und die w rmeleitende Ummantelung sorgen f r eine hohe Qualit t und f r eine lange Lebensdauer Das AQUALUC dient...

Page 2: ...en ist es wichtig dass das Produkt stets von zwei Personen montiert wird Dies gilt insbesondere ab einem L ngenma von einem Meter 1 m Dabei sollte auch darauf geachtet werden dass das Produkt m glichs...

Page 3: ...lung zu achten Hierbei ist die Menge des Klebers an die Gr e der Klebefl che anzupassen Individuelle L ngenanpassung optional Um das AQUALUC zu k rzen darf das Band nur im 90 Winkel an den gekennzeich...

Page 4: ...dius 50 mm 90 mm Biegeradius 50 mm 90 mm ABBILDUNG 3 AQUALUC RICHTIG K RZEN ABBILDUNG 2 BIEGERADIUS AQUALUC 14 25 33 50 mm BIEGERADIUS AQUALUC 25 HP 90 mm 13 5 mm 6 mm Biegerichtung LED Streifen LED S...

Page 5: ...Netzteil als auch Controller ausreichend Leistung zur Verf gung stellen k nnen 6 Betrieb und Sicherheitshinweise Nur eine Elektrofachkraft darf die Installation von LED Modulen mit Netzger t unter Bea...

Page 6: ...nde des LED Bandes erreicht ist trennen Sie das Band bitte vom Netz und entsorgen es nach den in Ihrem Land geltenden Umweltvorschriften Elektro und Elektronikabf lle d rfen nicht mit dem nor malen Ha...

Page 7: ...The high quantity of copper in the circuit paths the current limiter and the thermal conductive coating ensure high quality and a long lifetime The AQUALUC is only to be used for lighting purposes an...

Page 8: ...amaging the AQUALUC especially during unrolling or mounting it is important that two people install the product This is especially valid for a length of one meter 1 m or more Care should be taken that...

Page 9: ...used should be relative to the size of the required adhesive surface Individual length adjustment optional To shorten the AQUALUC the stripe may only be cut in a 90 angle on the marked points dashed l...

Page 10: ...0 mm 90 mm bending radius 50 mm 90 mm ILLUSTRATION 3 CORRECTLY SHORTENING THE AQUALUC ILLUSTRATION 2 BENDING RADIUS AQUALUC 14 25 33 50 mm BENDING RADIUS AQUALUC 25 HP 90 mm 13 5 mm 6 mm bending direc...

Page 11: ...ed to 230 V AC If you connect more than one AQUALUC to a power supply controller make sure that the power supply unit and the controller can provide sufficient power 6 Operation and safety advice Only...

Page 12: ...firm elastic white cartridge 290 ml 40100200 AQUALUC end cap set with PU syringe and 10 end caps 40100110 AQUALUC end caps 10 pieces 9 Disposal If the LED stripe can no longer be used disconnect it f...