WALK BEHIND POWER TROWEL INSTRUCTION MANUAL 

 

Technical Characteristics: 

Caractéristiques techniques: 

Technisch gegevens: 

Características Técnicas: 

Caracteristicas  

Técnicas

Qualit

às di tecnico

Model 

Modéle 

Type 

Modelo 

Modelo 

Modello 

MachineSerial Number 

Numéro de Série machine 

Serienummer machine 

Máquina número de série 

Numero de serie da maquina 

Numero di seria la macchina 

Engine Serial Number 

Numéro de Série moteur 

Serienummer motor 

Motor número de série 

Numero de serie do motor 

Numero di seria la motore 

Weight 

Masse 

Gewicht 

Masa 

Massa 

Massa 

 

 

 

Lbs 

(kg) 

B436 Walk Behind Power Trowel 

 

 

125 

(56.8) 

Noise Level 

Puissance acoustique 

Geluidniveau 

Nivel Sonoro 

Nivel del Ruido 

Potenza Acustica 

Pressure level 

Pression acoustique 

Geluidsdrukniveau 

Nivel Acustico 

Pressão Acústica

  

Pressione Acustica 

Vibration level 

Niveau de vibration 

Vibratieniveau 

Nivel de Vibracion 

Nivel de Vibração 

Livello di Vibrazione

 

Lwa  

(dB) 

Lpa 

(Db) 

a

hv 

(m/s

2

98 

99 

1.5 

 

 

The Technical Construction file is maintained at: 

Les fiches techniques de construction sont gardées à: 

Het technische constructie document wordt bewaard te: 

El archivo técnico de construcción se mantiene en: 

O arquivo técnico de construção é mantido no (a): 

L’originale dossier tecnico di construzione è conservato presso: 

 

 

The authorized representative is: 

Le représentant autorisé est: 

Gemachtigd vertegenwoordiger is: 

La representación autorizada es: 

O representante autorizado é: 

Il rappresentate autorizzato: 

 

 

 

 

 

Signature of Authorized Person: 

Signature de la personne autorisée: 

Handtekening van gemachtigd persoon: 

Firma de la persona autorizada: 

Assinatura de pessoa autorizada: 

Firma della persona autorizzata:

 

 

 

Typed name of Authorized Person: 

Nom dactlyographié de la personne autorisée: 

Getypte naam van gemachtigd persoon: 

Nombre de la persona autorizada: 

Nome datilografado da pessoa autorizada: 

Nome della persona autorizzata:

 

 

Robert S. Leggitt

 

Title of Authorized Person: 

Titre de la personne autorisée: 

Functie van gemachtigd persoon: 

Cargo de la persona autorizada: 

Titulo da pessoa autorizada: 

Posizione della persona autorizzata: 

 

 

Manager - Engineering

 

Date and place of issue: 

Date et place d’émission: 

Datum en plaats van afgifte: 

Fecha y lugar de emision: 

Data e lugar de emissão: 

Data e luogo di emissione:

 

05.03.2010

 

 

Mississauga, Ontario, Canada 

Mr. Robert Leggitt

 

Manager - Engineering 

Bartell Morrison Inc. 

375 Annagem Blvd. 

Mississauga, Ontario, Canada 

L5T 3A7 

Telephone: 905-364-4188 

Facsimile: 905-364-4202 

Bartell Morrison Inc. 

375 Annagem Blvd. 

Mississauga, Ontario, Canada 

L5T 3A7 

Telephone: 905-364-4200 

Facsimile: 905-364-4201 

21

375 ANNAGEM BLVD., MISSISSAUGA, ONTARIO, CANADA L5T 3A7, 905-364-4200 FAX 905-364-4201 

CREATED: 07/04 

REVISED: 05/10 

Mr.Richard Stanley

V.P. Operations

905-364-4185

V.P. Operations

03.06.2013

08/12

Richard Stanley

23

Summary of Contents for B430

Page 1: ...0 Rev Date 05 2010 Bartell Morrison Inc 375 Annagem Blvd Mississauga ON Canada L5T 2A7 Toll Free N A 1 866 501 1683 Local 1 905 364 4200 Fax 1 905 364 4201 OWNER S MANUAL BARTELL MORRISON INC artell O...

Page 2: ...son Inc No part of this work may be reproduced or transmitted in any form or by any means electronic or mechanical including photocopying and recording or by any information storage or retrieval syste...

Page 3: ...s turned off Serious burns may occur CAUTION ROTATING HAZARD Never place hands or feet inside safety guard rings Serious injury will result from contact with rotating blades CAUTION MOVING PARTS Befor...

Page 4: ...T 3A7 905 364 4200 FAX 905 364 4201 25 INDUSTRIAL DRIVE KEYPORT NEW JERSEY USA 07735 732 566 6400 FAX 732 566 5444 10 13 13 13 13 13 13 13 13 13 13 13 13 14 14 14 14 14 14 15 16 16 18 19 19 20 21 22 2...

Page 5: ...job you should start gradually and build up to full use Learn what your machine can do and how it will respond Refer to the engine manufacturer s manual for run in times Full throttle and control may...

Page 6: ...ion repair or replace a part or the whole of the defective component or equipment Our Warranty coverage is limited to the cost to repair or replace the defective portion of the equipment and a reasona...

Page 7: ...f parts or major service be sure to see your Bartell dealer For your convenience we have provided this space to record relevant data about your Walk Behind Power Trowel When in need of parts or servic...

Page 8: ...o o o Engine oil Change o o o Engine oil filter Replace o o Oil cooler Clean o o o o Cooling Fins Clean o o o o o Check clean o o o o o o Air cleaner Replace o Check o Air Intake Line Replace 2 yrs Ch...

Page 9: ...onents Use of a power washer will make clean up quick and easy especially if a non stick coating was applied prior to use In the Service Schedule above items that should be checked replaced or adjuste...

Page 10: ...wire exposed to secure to the lever Insert the cable into the fitting and tighten the screw Restore throttle to idle position 6 BELT GUARD Install after machine has been tested taking care that it doe...

Page 11: ...kwise until the stop screw is at the lowest position Fig 5 Step 4 Lift and install handle to position using the supplied four sets of lockwashers and nuts Do not torque greater than 18ft lb At the yok...

Page 12: ...prepare for their assembly Fig 7 and 8 Step 6 Remove air filter cover and air filter Fig 9 Step 7 Check for free moving engine throttle control lever and loosen pivot nut if necessary Fig 10 Step 8 P...

Page 13: ...p while pushing with slight pressure forward Fig 13 Step 11 Check operation of throttle control lever Fig 11 and 14 Step 12 Reinstall air filter and cover Fig 15 Step 13 Route engine safety shut off w...

Page 14: ...n when engine is warm increase throttle to maximum operation position 3600 rpm STARTING PROCEDURE COLD CLIMATE Follow same procedure as above but allow longer warm up period 3 to 5 minutes In cold wea...

Page 15: ...oper engine oil as recommended See previous chart Fill crankcase to levels as recommended in manufacture s engine manual SPARK PLUG Check and clean spark plugs regularly A fouled dirty or carboned spa...

Page 16: ...e for the protection of the electrical power supply cord Do not let the cord come into contact with the trowel blades under any circumstances If the cord does touch the blades immediately power down t...

Page 17: ...rage or transportation SETTING UP THE ELECTRIC POWER TROWEL STARTING THE ELECTRIC POWER TROWEL The Bartell Electric Power Trowel ships without the handle attached When installing the handle ensure tha...

Page 18: ...our hip against the shield pad on the handle for better control Bartell Electric Power Trowels operate at a constant speed which is achieved immediately after startup so there will be some kick With y...

Page 19: ...364 4200 FAX 905 364 4201 CREATED 07 04 REVISED 05 10 CONTROL BOX PIN2 PIN1 PIN3 CONTROL PLUG SAFETY SWITCH STOP START 1 3 2 4 COM NO DEADMAN OFF G W BL K W BL K BR BL 06 13 375 ANNAGEM BLVD MISSISSA...

Page 20: ...in position with one wrench tighten locknut 7 to secure in position with second wrench 7 This same procedure is to be followed with ALL arms from spider plate assembly and will ensure correct and exa...

Page 21: ...d on bottom of spider plate Trowels unevenly worn Spider plate seized Spider plate loose Trowel arms bent Adjusting screws carriage bolts incorrectly set use spider plate adjustment jig pg 13 Mainshaf...

Page 22: ...2 93 cm Up to 185 lb 75 kg B436 36 90cm 3hp 230V 1 Phase Electric Motor 10 x 14 25 x 36cm 6 x 14 15 x 36cm 8 x 14 20 x 36cm 38 1 2 98 cm Up to 165 lb 75 kg B446 46 120cm Honda GX160 Honda GX270 Honda...

Page 23: ...uipment functional aspects Principles for design EN 12100 1 2003 Safety of Machinery Basic Concepts general principles for design Part 1 Basic Terminology methodology EN 12100 2 2003 Safety of Machine...

Page 24: ...tive is Le repr sentant autoris est Gemachtigd vertegenwoordiger is La representaci n autorizada es O representante autorizado Il rappresentate autorizzato Signature of Authorized Person Signature de...

Page 25: ...LVD MISSISSAUGA ONTARIO CANADA L5T 3A7 905 364 4200 FAX 905 364 4201 CREATED 07 04 REVISED 05 10 06 13 375 ANNAGEM BLVD MISSISSAUGA ONTARIO CANADA L5T 3A7 905 364 4200 FAX 905 364 4201 25 INDUSTRIAL D...

Page 26: ...MISSISSAUGA ONTARIO CANADA L5T 3A7 905 364 4200 FAX 905 364 4201 CREATED 07 04 REVISED 05 10 06 13 375 ANNAGEM BLVD MISSISSAUGA ONTARIO CANADA L5T 3A7 905 364 4200 FAX 905 364 4201 25 INDUSTRIAL DRIV...

Page 27: ...a L5T3A7 Toll Free 866 501 1683 Local 905 364 4200 Fax 905 364 4202 www bartellmorrison com BARTELL MORRISON USA LLC 12 Industrial Drive Keyport New Jersey USA 07735 Toll Free 888 999 1570 Local 732 5...

Reviews:

Related manuals for B430