POLARIS COMFORT
- for Zone 1/21
POLARIS Touch Panel 5.7" / 10.4" / 12.1"
Installation
Technical data subject to change.
06/2017
EN 33/57
6.7
Ex i terminal compartment
DANGER
Accessories which have not been approved jeopardise the explosion protection.
Danger to life exists in an explosive atmosphere!
Only use POLARIS accessories!
The cover for the Ex i terminal compartment need not be used when deploying a
protective enclosure with protection class of at least IP20.
6.7.1
Connection of Ex i input device to the POLARIS (optional)
Do not connect the keyboard, mouse, trackball, touchpad, joystick or the hand scanner
while the power supply is active.
PS/2 for input devices
Terminal Interface
Colour
Signal
Remarks
X4
PS/2
WH/BR VCC
Supply voltage
X5
PS/2
GN/YE
GND
Mass connected to protective earth
X6
not used
X7
not used
X8
PS/2
BL
MS_CLK Mouse
clock signal
X9
PS/2
RD
MS_DATA Mouse
data signal
−
Make the connection between the POLARIS and the Ex i keyboard.
−
Connection by means of a 1.80-metre-long connection cable
−
Keyboard and mouse
Type 05-0068-0163
−
Keyboard and trackball/joystick
Type 05-0068-0172
−
Keyboard and touchpad
Type 05-0068-0183
(Optional: 3-metre-long connection cable)