Service, Inspection, Repair
MC 92N0
ex
-IS
- Mobile Computer
Type 17-A1A*-****/********
32/36
Subject to technical changes.
January 2022
8
Service, Inspection, Repair
Commissioning and service of Mobile Computers may be conducted exclusively by trained
and qualified staff! The staff is familiar with the installation, assembly, commissioning and
operation of the Mobile Computers, has been informed about the risks and has the
qualifications necessary for this work.
8.1
Service intervals
The mechanical state of the device should be regularly checked. The service intervals will
depend on the ambient conditions. We recommend that a service be conducted at least
once a year. Regular servicing is not necessary if the device is correctly operated in
accordance with the installation instructions and under appropriate consideration of the
ambient conditions.
DANGER
Prevent electrostatic charging in potentially explosive atmospheres.
There is a risk of fatal injury in an explosive atmosphere!
Do not dry wipe or clean devices.
8.2
Inspection
According to EN 60079-17, IEC 60079-17, EN 60079-19 and IEC 60079-19, the
owner/operator of electrical plants in potentially explosive atmospheres is obliged to have
these plants checked by an electrician to ensure that they are in a correct condition.
8.3
Service and repair work
In addition to Directive 99/92/EC, standards EN 60079-17, IEC 60079-17, EN 60079-19 and
IEC 60079-19 also apply to the servicing and repair as well as the testing of accompanying
operating devices.
Work connected with assembly/dismantling, operation and servicing may only be conducted
by trained specialists. All statutory requirements and other binding guidelines on
occupational health and safety, accident prevention and environmental protection must be
observed.