Appendix
APEX Pressurised Cabinet
Ex p Slot Printer
Page 56 of 60
01-37A2-7D0002_Manual_Exp-Slot-Printer_20220221_0_en.docx
Rev. 0
Reservation: We reserve the right to make any technical changes, if we consider them as required. Any changes, errors and misprints do not constitute any grounds for damage claims.
•The temperature of the circuit board is too
high.
STATUS indicator lights up continuously
red.
PAUSE light continuously red
DATA light continuously red.
The print head has not been replaced with a
genuine Zebra print head. Install a genuine
Zebra print head.
The STATUS light flashes red.
The printer cannot read the DPI setting of the
print head.
The NETWORK light remains off.
No Ethernet link is available.
NETWORK lights continuously green.
A 100Base-T link has been found.
NETWORK lights continuously yellow.
A 10Base-T link has been found.
NETWORK lights continuously red.
There is an Ethernet error. The printer is not
connected to the network.
Types of purge gas
Purified and dry instrument air is permissible as purge gas. In any case, a filter
must be installed upstream if the quality is not guaranteed with regard to foreign
particles. The following quality characteristics of the purge gas should be
fulfilled:
Residual dust: < 40 µm
Residual water: Dew point +3 °C
Residual oil content: 1 mg/m³