END OF LINE MONITORING
An end of line monitoring diode or an end of line monitoring resistor can be connected across the 24V+ and
0 terminals. If an end of line monitoring resistor is used, it must have a maximum resistance value of 3k ohms
and a minimum wattage of 0.5 Watts; or a minimum resistance value of 1.2k ohms and a maximum wattage
of 2 Watts.
12.0
MAINTENANCE
During working life of the product, little or no maintenance is required. SS316 is resistant to most of the acids,
alkalis and chemicals.
If abnormal or unusual environmental conditions occur due to accident etc., visual inspection is recommended.
To avoid electrostatic charge build-up, only exterior of the product can be cleaned with a damp cloth.
If spare parts are required, these can be supplied by BARTEC TECHNOR Company.
If any failure occurs, but not caused by human factor, the product can be returned to BARTEC TECHNOR for
free repair or replacement during warranty period.
13.0
CONDITIONS FOR SAFETY USE
i.
This apparatus is suitable to be used only in ambient temperature as stated on the label.
ii.
Other than product manufacturer, painting and surface finishing are not permitted by the third party.
iii.
When used in dusty atmosphere, flameproof cable entry devices or stopping plugs have to be
selected and installed carefully in order to maintain the IP rating (IP66/67) of the product.