6.2.1

 

Approved power packs and supply modules 

Power pack(s) for 

BCS3800

ex

Connection information: 

Interface: 

Type number/ 

 certification: 

Power pack for BCS3800

ex

 

with AC 100 V to 250 V in the 

version for Zones 1/21 

Connected to the socket in the power pack 
by means of a 4-pin connector. 

See chapter 4.1 Connection to type 17-

21BB-17 0x power packs 

RS232 or RS422 

17-21BB-1700 
 

IBExU09ATEX1091 

Power pack for BCS3800

ex

 

with DC 24V in the version for 

Zones 1/21 

Connected to the socket in the power pack 

by means of a 4-pin connector. 

See chapter 4.1 Connection to type 17-

21BB-17 0x power packs 

RS232 or RS422 

17-21BB-1701 

 

IBExU09ATEX1091 

Power pack for BCS3800

ex

 

with DC 12 V in the version 

for Zones1/21 

Connected to the socket in the power pack 

by means of a 4-pin connector. 

See chapter 4.1 Connection to type 17-
21BB-17 0x power packs 

RS232 or RS422 

17-21BB-1702 

 

IBExU09ATEX1091 

Compatible power pack(s) of predecessor models for BCS3800

ex

TTY power pack (polyester 

enclosure) for the BCS302

ex

 

in the version for Zone 1 

Connected to the socket in the power pack 

by means of a 4-pin connector. 

See chapter 4.2 Connection to power pack 

types 17-21BB-0217 and 17-21BB-0018 

TTY 

17-21BB-0217 

 

PTB 97 ATEX 1068 U

PTB 02 ATEX 1159 
PTB 01 ATEX 1014 U 

Power pack RS232 (polyester 

enclosure) for the BCS302ex 
in the version for Zone 1 

Connected to the socket in the power pack 

by means of a 4-pin connector. 

See chapter 4.2 Connection to power pack 

types 17-21BB-0217 and 17-21BB-0018 

RS232 

17-21BB-0218 

 
PTB 97 ATEX 1068 U

PTB 02 ATEX 1159 

PTB 01 ATEX 1014 U 

TTY power pack (polyester 

enclosure) for the BCS302ex 

in the version for Zones 1/21. 

Caution: Scanner is 
permanently connected! 

Remove the 4-pin connector and connect it 

directly to the terminals in the power pack. 

See chapter 4.3 Connection to power pack 

types 17-21BB-0219 and 17-21BB-0020 

TTY 

17-21BB-0219 

 

PTB 97 ATEX 1068 U

IBExU00ATEX1079 
PTB 01 ATEX 1014 U 

TTY power pack (polyester 

enclosure) for the BCS302

ex

 

in the version for Zones 1/21 

Caution: Scanner is 

permanently connected! 

Remove the 4-pin connector and connect it 

directly to the terminals in the power pack. 

See chapter 4.3 Connection to power pack 

types 17-21BB-0219 and 17-21BB-0020 

RS232 

17-21BB-0220 

 
PTB 97 ATEX 1068 U

IBExU00ATEX1079 

PTB 01 ATEX 1014 U 

Supply module for Polaris and BAT series: 

Interface converter installation 

module for connecting the 
BCS302ex and BCS3800ex 

to the Polaris series. 

Remove the 4-pin connector and connect it 

directly to the terminals in the power pack. 

See chapter 4.4 Connection to supply 

module type 05-0080-0378 

RS232 (internally 

occupies a COM 
interface in the 

Polaris) 

05-0080-0378 

 
IBExU03ATEX1148 U

 

Use only power packs and supply modules approved by BARTEC to supply power to the handheld 
scanner. 

Summary of Contents for BCS 3800

Page 1: ...User Manual Hand Held Scanner BCS 3800ex 17 21BA 0024 English...

Page 2: ......

Page 3: ...7931 597 119 info bartec de Germany User Manual Handheld Scanner BCS 3800ex Type 17 21BA 0024 ATEX Zone 1 and Zone 21 Version 1 00 Dokumenten Nr 11 21BA 7D0001 Status 18 January 2010 Technical data su...

Page 4: ...s Qualifications of the personnel working with the devices The user manual is written for all people who carry out assembly installation commissioning and service work on the product whereby the direc...

Page 5: ...urer Appropriate transportation suitable storage and careful operation are also essential for the perfect and safe operation of this product The handheld scanner is a hand guided electrical device use...

Page 6: ...nstructions serve to show the information being described and are not necessarily true to scale and they may deviate slightly from the actual construction of the device Particularly important points i...

Page 7: ......

Page 8: ...Health and Safety Recommendations 8 4 Connection Assignment 9 4 1 Connection to Power Pack Types 17 21BB 1700 17 21BB 1701 and 17 21BB 1702 9 4 2 Connection to Power Pack Types 17 21BB 0217 and 17 21...

Page 9: ...developed specially for use in hazardous potentially explosive areas and it is ATEX certified BCS 3800ex Handheld Scanner Type 17 21BA 0024 for Zone 1 in the intrinsic safety type of protection and Z...

Page 10: ...all types of bar code labels can be read e g coloured labels labels made of heat sensitive paper etc The handheld scanner allows data acquisition even under extreme conditions The handheld scanner rea...

Page 11: ...ternal capacitance Ci 52 0 F Maximum internal Inductance Li negligible Standards EN 60 079 0 2006 EN 60 079 11 2007 EN 61 241 0 2006 EN 61 241 11 2006 EN 61 000 6 2 2005 EN 61 000 6 4 2007 EN 60 950 1...

Page 12: ...0 cm 26 0 in 71 0 cm 28 in 7 5 mil code 39 16 5 cm 6 5 in 36 0 cm 14 0 in 38 0 cm 15 0 in 15 0 mil code 39 6 4 cm 2 5 in 76 2 cm 30 0 in 78 7 cm 31 0 in 20 0 mil code 39 3 8 cm 1 5 in 99 1 cm 39 0 in...

Page 13: ...User Manual Handheld Scanner BCS 3800ex Technical data subject to change without notice Issue 01 2010 Seite 5 von 21 FCC Ex Protection Type Type label 2 5 Product Marking...

Page 14: ...ALIANO CLASSE 1 PRODOTTO AL LASER DI CLASSE 1 CLASSE 2 LUCE LASER NON FISSARE IL RAGGIOPRODOTTO AL LASER DI CLASSE 2 DUTCH NEDERLANDS KLASSE 1 KLASSE 1 LASERPRODUKT KLASSE 2 LASERLICHT NIET IN STRAAL...

Page 15: ...longer be operated safely after harmful effects or general irregularities e g penetration of water fluids effect of temperatures outside the specified range etc Recommendation Don t dry wipe and clean...

Page 16: ...light diode As with any bright source of light for example the sun the user should avoid looking directly into the light beam However momentary or brief exposure to a Class 2 laser is not considered h...

Page 17: ...into the power pack 3 Run the 4 core shielded cable for the BCS 3800ex handheld scanner into the power pack 4 Connect the 4 pin socket to the 4 core shielded end of the cable in accordance with the w...

Page 18: ...the bar codes in the programming manual Note The maximum length of the connection cable from the power pack to the handheld scanner is 7 9 m The shielded connection cable from the handheld scanner is...

Page 19: ...2 mm to 2 5 mm Conductor cross section flexible with wire end ferrule without plastic cover 9 mm 0 25 mm to 1 5 mm Conductor cross section flexible with wire end ferrule with plastic cover 9 mm 0 25 m...

Page 20: ...nnected to PE X5 TxD TxD RS 232 X6 Shield Shield RS 232 RS 422 internally connected to PE X7 T T RS 422 X8 T T RS 422 Ex i junction box Terminal Designation X9 RxD RxD RS 232 X10 GND GND RS 232 intern...

Page 21: ...scanner Suitable for handheld scanner type 17 21BA 0020 and type 17 21BA 0024 Illustration 4 2 Connection Power Pack to BCS 3800ex The BCS 3800ex handheld scanner is the successor to the BCS 302 Duste...

Page 22: ...8 The type 05 0080 0378 supply module is used in the POLARIS series to connect a handheld scanner The module is suitable for supplying power to the following handheld barcode scanners Type 17 21BA 002...

Page 23: ...1 x User manual and a CD with the programming manual for the BCS 3800ex Software installations and adjustment possibilities see HANDHELD Products Manual User Guide for 3800i Industrial Handheld Linear...

Page 24: ...t use it Take care when laying the connection cable that it will not cause anyone to trip and the handheld scanner to be pulled down as a consequence 5 1 Scanning Technology The scanner has a red las...

Page 25: ...programmable codes in this manual e g the interface parameters for RS 232 or RS 422 enable disable and settings for the different bar code types settings for the scanner such as volume trigger mode t...

Page 26: ...r The devices may be used only if they are in a technically perfect condition Before you use the handheld scanner for the first time the system must be installed perfectly and the scanner must be conn...

Page 27: ...EX 1159 PTB 01 ATEX 1014 U Power pack RS232 polyester enclosure for the BCS302ex in the version for Zone 1 Connected to the socket in the power pack by means of a 4 pin connector See chapter 4 2 Conne...

Page 28: ...ce a year Regular maintenance is not necessary if operated appropriately in conformance with the installation instructions and with due consideration to the ambient conditions Inspektion Under IEC 600...

Page 29: ...49 7931 597 119 We cannot guarantee any contractually agreed processing times for devices that are sent in without an RMA number The RMA guide and the RMA form are available on our homepage for downl...

Page 30: ...Declaration of Conformity Handheld Scanner BCS 3800ex Technical data subject to change without notice Issue 01 2010...

Page 31: ......

Page 32: ...E_11 21BA 7D0001 01 2010 BART EC Automation Technology BARTEC GmbH Germany Max Eyth Stra e 16 97980 Bad Mergentheim Tel 49 7931 597 0 Fax 49 7931 597 119 info bartec de www bartec group com...

Reviews: