Information of this FAQ 

 

 

Read carefully before commissioning the device. 

 

The FAQ is an additional description to the available user manual and part of the device. 
The FAQ is directed at all persons who are entrusted with handling the device. 
Knowledge of the safety instructions and warnings in this FAQ and strict compliance with them 
is essential for safe handling.  

‒ 

Carefully read the FAQ and especially the safety instructions before using the device. 

‒ 

Make the FAQ accessible to all people who are entrusted with handling the device. 

 
Warnings are used in this User Manual to warn of the risks of damage to property and personal 
injuries. 

 

 

1.1

 

Reference documents 

 

 

All documents are available online from the following websites: 

‒ 

BARTEC: 

www.bartec.com or

 

http://automation.bartec.de

 

 

Document BARTEC 

Explanation 

Quick Start Guide of: 

 

Agile X IS 
 

It contains: 

 

Guidelines on commissioning and the safe use of 
hand-held scanners (including installation, safety 
information related to explosion protection and 
information regarding programming)  

Symbol 

Explanation 

 

Important advice and information for the effective, efficient and environmentally 
sound use of the product. 

 

Condition that must be met before the subsequent actions can be performed. 

 

Individual steps you must take. 

1., 2., … 

Various steps to be performed in the order specified. 

 

Indication of the results of a step or of several steps for monitoring success. 

Summary of Contents for Agile X IS Series

Page 1: ...on bartec de GERMANY Internet www bartec com FAQ Frequently Asked Questions 10 1 Industry Tablet PC PXE boot on Agile X IS series Required hardware BIOS setup Relevant for Agile X IS Status November 2020 Reservation Technical data subject to change without notice Changes errors and misprints may not be used as a basis for any claim for damages ...

Page 2: ......

Page 3: ...2020 Subject to technical changes 10 2020 1 Information of this FAQ 2 1 1 Reference documents 2 2 About PXE 4 3 Notes to PXE 4 4 Required software and hardware 4 4 1 Required software 4 4 2 Required hardware 5 4 3 Important note for connection of keyboard and mouse 5 5 PXE BIOS setup 7 ...

Page 4: ...is User Manual to warn of the risks of damage to property and personal injuries 1 1 Reference documents All documents are available online from the following websites BARTEC www bartec com or http automation bartec de Document BARTEC Explanation Quick Start Guide of Agile X IS It contains Guidelines on commissioning and the safe use of hand held scanners including installation safety information r...

Page 5: ...ormation for the user to make full use of the device This manual includes a description of the system functions and capabilities contingencies and modes of operation and step by step procedures for system access and use Guidelines on commissioning and the safe use of hand held scanners including installation safety information related to explosion protection and information regarding programming ...

Page 6: ...ur PXE server must be identical that PXE boot can work correct 4 Required software and hardware Agile X IS series only support Ethernet and must use one of the following accessories to setup and proceed PXE 4 1 Required software We recommend to use the latest available BIOS version for this devices The latest version is listed on BARTEC support Download page https automation bartec de tabletpcE ht...

Page 7: ...are version Agile X IS series 4 3 Important note for connection of keyboard and mouse When using mouse and keyboard make sure that the USB port on the Agile X IS can only be used with Ex approved accessories Use of USB Hub is not allowed WARNING Improper use of USB port on Agile X IS can damage the device Only use the BARTEC USB stick Type 17 A1Z0 0027 for data exchange via the USB port Don t conn...

Page 8: ...Agile X IS series FAQ PXE boot FAQ Subject to technical changes 10 2020 6 11 Not allowed Wrong connection via USB hub on Ex i USB port Correct connection via docking station ...

Page 9: ...E BIOS setup 1 Connect external keyboard to the Agile X IS via docking station 2 Start or restart the device and enter BIOS Press DEL ENTF key in start screen with BARTEC logo 3 Check that BIOS version is v1 08 or later picture shows example for BIOS version v1 11 4 Go to Advanced and select Miscellaneous Configuration ...

Page 10: ...PXE boot FAQ Subject to technical changes 10 2020 8 11 5 Go to OS Selection and select your operating system Windows 8 X for Windows 8 1 or Windows 10 operating system 6 Go to Advanced and select Network Stack Configuration ...

Page 11: ...chnical changes 09 2020 Subject to technical changes 10 2020 Enable Network Stack and make your settings compliant to your server Default Network Stack Enabled IPv4 PXE Support Enabled IPv6 PXE Support Enabled 7 Go to Advanced and select CSM Configuration ...

Page 12: ...e X IS series FAQ PXE boot FAQ Subject to technical changes 10 2020 10 11 Setup CSM Configuration to Disabled 8 Go to Boot and select Boot mode select according to your server to UEFI Boot option to USB LAN ...

Page 13: ...FAQ Agile X IS series FAQ PXE boot 11 11 Subject to technical changes 09 2020 Subject to technical changes 10 2020 9 Go to Save Exit Select Save Changes and Exit to leave BIOS ...