Technical Data
POLARIS Remote
POLARIS Remote KVM Analog
24/37
Technical data subject to change without notice.
07/2018
6.4.9
Establishing CAT cable
Two RJ45 connectors for customer assembly are enclosed for the connection.
Illustration 13: RJ 45-plug
For an Ethernet connection, observe the instructions in Chapter 4.5 "EMC".
Assembly
The plug connector can be used for cables with an external diameter of 4.5...8.0 mm
(suitable for LAN STP cables, CAT.7 4x2x23 AWG; part number 129543). The diameter
of the core insulation may not exceed 1.6 mm! The plug connector can be rewired up to
20 times (only with the same core cross-section).
(1)
Slide the pressure nut and the connector
housing over the cable (Fig 1).
Optional: colour coding can be put on the
pressure nut.
(2)
Strip 30 mm of cable sheath length.
(3)
Fold the braided shielding back over the cable
sheath.
(4)
Shorten the braided shielding to a length of
approx. 8 mm and fix it in place with the
enclosed adhesive shielding film (fig. 2).
(5)
Unravel the twisting and arrange the cores in
accordance with wiring diagram.
(6)
Lift up the actuating flap and separate the
shielding lugs slightly (see illustration).
Do not open any actuating flap that is not
necessary for the wiring.
(7)
Run the individual core wires into the
chambers in the actuating flap.
(8)
Press the shielding lugs together so that they
come into contact with the braided sheath (see
illustration).
Prevents the plug connector slipping away
when the cores are being connected.