Barcode Hand Scanner
BCS 160
ex
Series, Types 17-21BA-M31S/…….. and 17-21BA-M32S/……..
Commissioning
Technical data subject to change without notice.
Revision A / Status: 01/2014
33/48
Maximum ranges
Type
Interface
Maximum length
Ex base station
to the power pack
17-21BB-1707/0000 RS232/RS422 9.8 m
Non-Ex base station to
the PC or other host
03-9849-0064
RS232/RS422 9.8 m
Power pack to the PC
or other host
17-21BB-1703/0000 RS232
20 m
17-21BB-1705/0000 RS422
1000 m
The hand scanner must be adapted at least to the following PC or host parameters so that
a connection can be established.
1.
Baud rate
2.
Data frame consists of data bit, parity and stop bit
3.
Handshake protocol/ flow control
For more information and parameters, please see the programming manual from Sick.
5.6.2
USB Connection
When using the Ex base station, the following power pack must be used for supply
voltage and data transmission.
The hand scanner is connected to a power pack of the following type.
Power pack, DC 24 V, USB
17-21BB-1704/0000
Power pack, AC 230 V, USB
17-21BB-1706/0000
Non-Ex base station
Can be connected directly to a USB interface on the PC or host.
Maximum ranges
Type
Interface
Maximum length
Ex base station
to the power pack
17-21BB-1707/0000 USB
3.8 m
Non-Ex base station to
the PC or other host
03-9849-0064
USB
3.8 m
Power pack to the PC
or other host
17-21BB-1704/0000 USB
5 m
17-21BB-1706/0000 USB
For more information and parameters, please refer to the Programming Manual from
Sick.
Summary of Contents for 17-21BA-M31S Series
Page 2: ......
Page 6: ...Blank...