Operation 

 

Death or serious injury through improper 
use. 

 

The miniature control and display unit may 
be operated only within the technical limits
that apply to it (see page 1). 

 

Maintenance and fault clearance 

 

Death or serious injury through damaged 
flameproof encapsulation. 

 

The threaded gaps must be protected.
They must not be machined or varnished
at any time later. 

 

Replace defective parts in the flameproof
encapsulation with original parts immedi-
ately. 

 

Risk of serious injury due to incorrect 
proceedings. 

 

Only authorized qualified personnel may
do any of the work relating to maintenance
and fault clearance. 

 

IEC/EN 60079-17 must be observed. It is 
recommended to formulate a maintenance
plan according to this standard. 

 

 

Maintenance work 

The operator of the miniature control and 
display unit must keep it in good condition, 
operate it correctly, monitor it and clean it
regularly. 
 

 

Visually inspect the threaded gap. 

 

Visually inspect the flameproof encapsu-
lation for damage. 

 

Check sealings for effectiveness.  

 

Replace old or damaged sealings with
new original seals. 

 

Check that the connecting terminals,
cable & conductor entries are secure. 

 

 

Note 

In the course of maintenance particular atten-
tion must be paid to checking that the parts
essential for the type of protection and proper
functioning are in good condition. 

 

Fault Clearance 

The miniature control and display unit is defec-
tive if the flameproof encapsulation is damaged
and/or if one of the components does not 
function any longer 
 
 

 

In this case:  

 

Replace defective parts in the flameproof 
encapsulation with original parts immedia-
tely. 

 

Replace or repair the defective compo-
nents with original parts.  

 

 

Note 

Follow the components mounting instructi-
ons/operating instructions to replace or repair 
the components. 

 

Accessories, spare parts 

See BARTEC catalogue. 
 

Disposal 

The components in the miniature control and 
display unit contain metal and plastic parts. 
The statutory requirements for disposing of 
electronic scrap must be observed therefore 
(e.g. disposal by an approved disposal compa-
ny). 
 

Service address 

BARTEC GmbH  
Max-Eyth-Straße 16  
97980 Bad Mergentheim 
Germany 
Tel.: 

+49 7931 597-0 

Fax: 

+49 7931 597-119 

 

Dimensions in mm (in) 

Standard: 

– 

Cable entry type 07-9.../…. 

– 

Front flange 

 48/72 (1.89/2.84) 

 

 

 

Order number 

Diameter  

Overall length  

07-6111-..../... 30 

(1.2) 

 55 (

 2.2) 

07-6121-..../.... 45 

(1.8) 

 55 (

 2.2) 

07-6131-..../.... 60 

(2.4) 

 60 (

 2.4) 

 

 

Cable entry, type 07-9.../…. 

 

 

Front flange 

 48/72 

 
 
 

 

 

 

Summary of Contents for 07-61.1 Series

Page 1: ...rial Aluminium surface bare coated Stainless steel Brass surface bare nickel plated Cover closure Cheese head screw ISO 4762 M4x14 A2 70 or ISO 4762 M5x14 A2 70 Dimensions See page 3 01 6100 7D0002 B 02 15 STVT 283184 Note on instructions When working in hazardous areas the safety of personnel and equipment depends on compli ance with the relevant safety regulations The people in charge of install...

Page 2: ...display unit through incorrect transport or incorrect storage Transport and storage is permissible in original packaging only Assembly disassembly Risk of serious injury due to incorrect proceedings Only authorized and qualified personnel may do any of the assembly disassembly installation and commissioning work Always disconnect the miniature control and display unit from voltage before as sembly...

Page 3: ...spect the threaded gap Visually inspect the flameproof encapsu lation for damage Check sealings for effectiveness Replace old or damaged sealings with new original seals Check that the connecting terminals cable conductor entries are secure Note In the course of maintenance particular atten tion must be paid to checking that the parts essential for the type of protection and proper functioning are...

Page 4: ...ax Eyth Straße 16 97980 Bad Mergentheim Germany Tel 49 7931 597 0 Fax 49 7931 597 119 info bartec de www bartec de Reservation Technical data subject to change without notice Changes errors and misprints may not be used as a basis for any claim for damages EN 4 4 01 6100 7D0002 B 02 15 STVT 283184 ...

Reviews: