background image

 

 

   

 

 

Operational Instruction 

(Translation)

 

  Miniature Control and Display Unit  

Type 07-61.1-…./…. 

 

 

BARTEC 

GmbH  Max-Eyth-Straße 16  

97980 Bad Mergentheim 

Germany 

Tel.:  +49 7931 597-0 

Fax:  +49 7931 597-119 

[email protected] 

www.bartec.de 

Reservation  Technical data subject to change without notice. Changes, errors and 

misprints may not be used as a basis for any claim for damages. 

EN 1/4 

 

 

 

 

 

 

 

 

 

 

Explosion protection 

 

Technical data 

 

Maximum Ex type of protection 

Depends on the installed components; ob-
serve the specifications on the type label.  
 

ATEX/IECEx 

 

II 2G 

Ex d e [ib] IIC T6, T5  
or T4 Gb 

 

II 2(1)G  Ex d e [ia Ga] IIC T6, T5  

or T4 Gb 

 

II 2G 

Ex d e IIC T6 or T5 Gb 

 

 

II 2D 

Ex tb [ib] IIIC T80 °C or 
T95 °C Db  

 

II 2(1)D  Ex tb [ia Da] IIIC T80 °C  

or T95 °C Db 

 

II 2D 

Ex tb IIIC T80 °C or  
T95 °C Db 

 

0044 

Certification 

ATEX 

EPS 14 ATEX 1 696 

 

IECEx 

IECEx EPS 14.0042 

INMETRO 

Ex d e [ib] IIC T6…T4 Gb 
Ex d e [ia Ga] IIC T6…T4 Gb 
Ex d e IIC T6…T5 Gb 
Ex tb [ib] IIIC T80 °C…T95 °C Db 
Ex tb [ia Da] IIIC T80 °C…T95 °C Db 
Ex tb IIIC T80 °C…T95 °C Db 

 

Certification 

NCC 14.02943 

 

TC RU C-DE.

ГБ

06.

В

.00443 

Ambient temperature ranges 

Depending on the installations; observe the 
specifications on the type label. 
 
-20 °C up to max. +70 °C 
(-4 °F up to max. +158 °F) 

Approved for Zones 

1, 2 and 21, 22 

Components 

Follow the components manufacturer’s 
mounting instructions and safety instructions. 

Other applicable documents 

– 

Circuit diagram 

– 

Mounting instructions/operating instruc-
tions for the installed components 

– 

Delivery note  

The retention of these documents is manda-
tory. 

Electrical data 

Rated insulation voltage:  max. 690 V 
Rated current/installation 
elements: 

 
max. 21 A 

Power loss: 

max. 8 W 

Nominal connection cross 
section: 

 
max. 2.5 mm² 
(14 AWG), 
see type label 
for precise 
details 

Protection class 

Max. IP 66 (EN 60529) 

Mechanical strength 

Impact energy: max. 7 Nm 

Enclosure material 

– 

Aluminium, surface bare/coated 

– 

Stainless steel 

– 

Brass, surface bare/nickel-plated 

Cover closure 

Cheese head screw,  
ISO 4762-M4x14-A2-70 or  
ISO 4762-M5x14-A2-70 

Dimensions 

See page 3. 

 

01-6100-7D0002/

B-0

2/

15-STVT-283184

 

Note on instructions 

When working in hazardous areas, the safety of
personnel and equipment depends on compli-
ance with the relevant safety regulations. The
people in charge of installation and mainte-
nance bear a special responsibility. It is essen-
tial that they have an exact knowledge of the
applicable rules and regulations. 
The instructions provide a summary of the most
important safety measures and must be read by
everyone working with the product so that they
will be familiar with the correct handling of the
product. 
The instructions have to be kept for future
reference and must be available throughout the 
expected life of the product. 
 

Description 

The miniature control and display unit, type 07-
61.1-…./…. and type 07-662.-…./…., serves as 
a flameproof enclosure for switching, control,
regulating and display devices in an industrial
quality.  Alternatively, certified intrinsically safe
or associated apparatus can be fitted too. 
The miniature control and display units consist
of an enclosure with the “flameproof enclosure”
type of protection and optionally a bearing
assembly with shafts and/or a flange with
“flameproof”-certified washers. 
For connection purposes, there is either a
junction box with “increased safety” type of
protection or Ex d certified cable and conductor
entries. 
The miniature control and display unit can be 
used in hazardous areas in Zones 1 and 2 in
accordance with the certified explosion hazard
sub-groups IIA, IIB and IIC and the temperature
class T4/T5/T6, as well as in Zones 21 and 22
in accordance with the certified max. surface
temperature (see type label). 
If the miniature control and display units contain 
intrinsically safe circuits or Ex i components, the
electrical limits that are decisive for “intrinsic 
safety” must be adhered to. 

 

Summary of Contents for 07-61.1 Series

Page 1: ...rial Aluminium surface bare coated Stainless steel Brass surface bare nickel plated Cover closure Cheese head screw ISO 4762 M4x14 A2 70 or ISO 4762 M5x14 A2 70 Dimensions See page 3 01 6100 7D0002 B 02 15 STVT 283184 Note on instructions When working in hazardous areas the safety of personnel and equipment depends on compli ance with the relevant safety regulations The people in charge of install...

Page 2: ...display unit through incorrect transport or incorrect storage Transport and storage is permissible in original packaging only Assembly disassembly Risk of serious injury due to incorrect proceedings Only authorized and qualified personnel may do any of the assembly disassembly installation and commissioning work Always disconnect the miniature control and display unit from voltage before as sembly...

Page 3: ...spect the threaded gap Visually inspect the flameproof encapsu lation for damage Check sealings for effectiveness Replace old or damaged sealings with new original seals Check that the connecting terminals cable conductor entries are secure Note In the course of maintenance particular atten tion must be paid to checking that the parts essential for the type of protection and proper functioning are...

Page 4: ...ax Eyth Straße 16 97980 Bad Mergentheim Germany Tel 49 7931 597 0 Fax 49 7931 597 119 info bartec de www bartec de Reservation Technical data subject to change without notice Changes errors and misprints may not be used as a basis for any claim for damages EN 4 4 01 6100 7D0002 B 02 15 STVT 283184 ...

Reviews: