INDEX

IMPORTANT NOTES

Congratulations  on  your  purchase  of  this  high  quality  BARSKA 

microscope.  With  proper  care,  this  microscope  will  provide  many 

years  of  use.  Please  read  the  following  instructions  before 

operating this instrument.
1. Do not attempt to disassemble the instrument. This product has  
    been carefully assembled at the factory and should only be     
    examined by a factory-trained technician.  
2. This instrument should only be used in an environment with an  
    indoor temperature range of 32

o

F to 104

o

F.

3. Do not use this instrument in an environment with a lot of dust.
    Cover the instrument when not in use.
4. Do not subject the instrument to shock.

Maintenance............................................
Model AY11240/Model AY11238..................
Model AY11228/Model AY11232..................
Model AY11230/Model AY11234..................
Model AY11236........................................
Warranty Information................................

1
2-5
6-9
10-13
14-18
Back Cover

1

MAINTENANCE

Proper care and storage of this instrument is essential. Please read 

the following guidelines:

1. Keep the instrument in a dry and moisture-free location.

2. Do not expose to acid, alkali fumes or moisture.

3. Keep optical parts clean and free of dust. To clean optical parts  

    gently wipe with lens cleaning tissue and a mixture of alcohol  

    and diethyl ether. Depending on weather conditions, the  

 

    following are the recommended mixture ratios:

    Wet weather: 1:2

    Dry Weather: 1:1

4. After use, cover the instrument with the plastic dust cover.

5. If instrument is to be stored for an extended period of time,   

   remove the eyepiece and oculars and store in a moisture-proof  

   container.

MODEL AY11240/AY11238

2

MICROSCOPE USAGE

BARSKA Model AY11240 and Model AY11238 are designed for 

biological studies such as specimen examination. They can also   

be used for examining bacteria and for general clinical and medical 

studies. Simple design and use is especially useful for school 

classroom instruction.

CONSTRUCTION

BARSKA Model AY11240 is a fixed tube type. For comfortable 

observation, the arm can be easily tilted at any angle from 90

o

 

vertical to 45

o

 level. It is also equipped with a coarse adjustment 

and fine adjustment as well as a space limiter to protect the 

objective from contacting and damaging the specimen. BARSKA 

Model AY11238 features a monocular tube that is slanted at a 45

o

 

angle. The head rotates 360

o

. The Eyepiece Set Screw prevents 

the eyepiece from falling out of the tube.

Coarse 

Adjustment

Knob

Fine 

Adjustment

Knob

Stand

5-Hole

Diaphragm

and Condenser

Concave

Mirror

Stage

Spring Clips

Objectives

Barrel

Revolving Turret

Eyepiece

Coarse 
Adjustment
Knob

Fine 
Adjustment
Knob

Stand

5-Hole
Diaphragm
and Condenser

Lamp 
On/Off
Switch

Lamp 

Power
Cord

Stage

Spring 
Clips

Objectives

Rotating Head

Revolving 
Turret

Eyepiece

Stage Height
Limit Adjustment

Monocular Tube

Eyepiece 
Set Screw

Model AY11240

Model AY11238

Summary of Contents for AY11228

Page 1: ...tify the customer accordingly BARSKA reserves the right to replace any product which has been discontinued from its product line with a new product of comparable value and function This warranty shall be void and of no force of effect in the event a covered product has been modified in design or function or subjected to abuse misuse mishandling or unauthorized repair Further product malfunction or...

Page 2: ...ather 1 2 Dry Weather 1 1 4 After use cover the instrument with the plastic dust cover 5 If instrument is to be stored for an extended period of time remove the eyepiece and oculars and store in a moisture proof container MODEL AY11240 AY11238 2 MICROSCOPE USAGE BARSKA Model AY11240 and Model AY11238 are designed for biological studies such as specimen examination They can also be used for examini...

Page 3: ... parts before assembling 2 Attach 4x 10x and 40x objectives to revolving turret 3 Place the specimen on the stage and secure with spring clips NOTE The cover glass must face upward the thinner glass is the cover glass otherwise when the 40x objective is used the specimen cannot be observed Observation is best when the thickness of the cover glass is 0 1 1 1mm and the cover glass is 0 17mm 4 Plug p...

Page 4: ...ustment knob until the image is in sharp focus When using other objectives rotate the fine focus adjustment until the image is in focus Model AY11240 Model AY11238 6 MODEL AY11228 AY11232 MICROSCOPE USAGE BARSKA Model AY11228 and Model AY11232 are designed for biological studies such as specimen examination They can also be used for examining bacteria and for general clinical and medical studies S...

Page 5: ...ATION 1 Remove components from package identify all parts before assembling 2 Tighten the knob on the stand to prevent the elevator from sliding down 3 Fix the binocular body on the stand with the tightening screw 4 Check the input voltage to ensure that it conforms to the microscopes requirement SELECTING THE ILLUMINATION 1 Depending on microscope use select oblique or transmitted illumination 2 ...

Page 6: ...eft eyepiece and bring a specific point into focus using the focus knob b By turning the diopter ring adjustment for the left eyepiece bring the same point into sharp focus c Then bring the same point into focus through the right eyepiece by turning the right diopter ring d With more than one viewer each viewer should note their own diopter ring position for the left and right eyepieces then befor...

Page 7: ...RATION 1 Remove components from package identify all parts before assembling 2 Tighten the knob on the stand to prevent the elevator from sliding down 3 Fix the binocular body on the stand with the tightening screw 4 Check the input voltage to ensure that it conforms to the microscopes requirement SELECTING THE ILLUMINATION 1 Depending on microscope use select oblique or transmitted illumination 2...

Page 8: ...o both eyes at the same time the diopter ring may need adjustment DIOPTER RING ADJUSTMENT 1 To adjust the eyepiece for viewing with or without eyeglasses and for differences in acuity between the right and left eyes follow the following steps a Observe an image through the left eyepiece and bring a specific point into focus using the focus knob b By turning the diopter ring adjustment for the left...

Page 9: ...ce 16 PARTS LIST OPERATION 1 Remove all components from package Identify all parts before assembling instrument 2 Attach 4x 10x and 40x objectives by screwing into revolving turret Tighten and secure to maximum finger pressure only 3 Place the specimen on the stage and secure with spring clips NOTE The cover glass must face upward the thinner glass is the cover glass otherwise when the 40x objecti...

Page 10: ...e wiped off all of the cedar oil OPERATION cont ADJUSTING THE CONDENSER APERTURE 1 The numerical aperture of the condenser should match the numerical aperture of the objective being used 2 To make sure that the objectives are imaging properly especially the 40x and 100x follow this procedure 1 Take off the eyepiece 2 Look through the eyepiece 3 The smallest circle or light that you can see is the ...

Reviews: