background image

NEUTRAL

NEUTRAL

LINE

FXA

 

35

0W Series

Installation Instructions

200701

67

  

R

EV 1 - 

07/20

 

3

800-533-3948 www.barronltg.com

Wiring 

Electrical connections should be made inside J-box. 

Cap all unused leads to prevent shorting. 

Make electrical connections as follows: 

Black - Line

White - Neutral

Green/Yellow Green - Ground

Purple - Dim +

Gray - Dim -

Note:

 This fixture auto adjusts for voltages from 

          120VAC-277VAC

Important:

 Weatherproof your outdoor installation, be sure to seal 

all holes in the housing such as the mounting, conduit, plugs, 

sensors, photocontrols, etc. with silicone sealant.

1. Check incoming voltage to the LED driver. Must be at least a minimum

of 120VAC and no greater than 277VAC.

2. Are all the LEDs on the light engine “OFF”? If so, LED driver may be defective. Using a voltmeter, check to see if

voltage is present at the output of the power supply. If low or no voltage, then replace the power supply.

3. If any individual LEDs are “OFF” the LED light engine is defective. Please have the serial number off the light engine

available when you contact technical support.

4. If the unit is equipped with a photocell, check the photocell to make sure it’s functioning properly.

Wire Connection - Dimming

Photocontrol

Troubleshooting

If unit does not turn “ON”

Green/Yellow Green

Purple

DIM+

Gray

DIM-

%ODFN

Line

White

Neutral

Ground

Figure 3

Reviews: