NEUTRAL
NEUTRAL
LINE
FXA
35
0W Series
Installation Instructions
200701
67
R
EV 1 -
07/20
3
800-533-3948 www.barronltg.com
Wiring
Electrical connections should be made inside J-box.
Cap all unused leads to prevent shorting.
Make electrical connections as follows:
Black - Line
White - Neutral
Green/Yellow Green - Ground
Purple - Dim +
Gray - Dim -
Note:
This fixture auto adjusts for voltages from
120VAC-277VAC
Important:
Weatherproof your outdoor installation, be sure to seal
all holes in the housing such as the mounting, conduit, plugs,
sensors, photocontrols, etc. with silicone sealant.
1. Check incoming voltage to the LED driver. Must be at least a minimum
of 120VAC and no greater than 277VAC.
2. Are all the LEDs on the light engine “OFF”? If so, LED driver may be defective. Using a voltmeter, check to see if
voltage is present at the output of the power supply. If low or no voltage, then replace the power supply.
3. If any individual LEDs are “OFF” the LED light engine is defective. Please have the serial number off the light engine
available when you contact technical support.
4. If the unit is equipped with a photocell, check the photocell to make sure it’s functioning properly.
Wire Connection - Dimming
Photocontrol
Troubleshooting
If unit does not turn “ON”
Green/Yellow Green
Purple
DIM+
Gray
DIM-
%ODFN
Line
White
Neutral
Ground
Figure 3