background image

INSTALLATION INSTRUCTIONS

800.533.3948 • www.barronltg.com 

3

40070017 REV 1 01/2019

ACCESSORIES

 

(insert 3528 or 5050 for the **** for the correct version)

• RFX-CSS-**** is designed to join (2) cut sections together. (Fig. 2)

• RFX-CSS-FLEX-**** is designed to join (2) cut sections together with 2” 

  wire spacing, allowing the FTK tape to bend or turn corners. (Fig.3)

• RFX-CSP-**** is designed to provide wire leads to a cut section of FTK 

  tape to assist with connection to the driver. (Fig. 4)

NOTE:

• When connecting lengths together keep all negatives (-) on one side and all 

   positives (+) on the other. Failure to do so will leave a non-working section. 

   (Fig. 5)

• Peel the silicon sleeve back approximately 1/8” and slide the tape under the 

  connector terminals, aligning the copper pads with the terminal prongs. 

  Snap cover down to secure the FTK tape in place. (Fig. 6)

TROUBLE SHOOTING

Product will not light:

• Verify that there is power to the receptacle feeding the product.

• Check the GFCI and see if it is tripped.

• Check the driver and make sure it has power.

• Verify product porlarity is correct.

Product does not light for the first 8”- 30”:

• Product was cut incorrectly. It will be necessary to re-cut the product at the 

  correct designated locations and reassemble.

Product has a dark section in the run:

• This indicates the product was pulled, twisted or kinked and the circuitry 

   was damaged.

• It will be necessary to cut new product or cut out the damaged section and 

   splice a new piece in its place.

FTK

Fig. 2

Fig. 3

Fig. 4

Fig. 5

Fig. 6

Reviews: