BARRETT 2061 OPERATING AND TECHNICAL MANUAL
1
Specifications
Output level to phone line
Nominally –0 dBm
Input level from phone line
Nominally –0 dBm
Frequency response
300 to 3000 Hz ± 2 dB
Output impedance to phone line
600 ?
VOX sensitivity Adjustable internally
VOX hang time
0.5 seconds
Ultimate hybrid balance
-50 dB measured with a single tone
Transceiver interface
Rx audio input
Balanced 600 ? @ 0 dBm
Tx audio output
Balanced 600 ? @ 0 dBm
Frequency response
300 to 3200 Hz ± 2 dB
VOX key output
Open collector
Switching speed
5 mS
General
Telephone line connector
RJ-11C
Local telephone set connections
RJ-11C
Connector to transceiver
DB-25
Indicators
"CONNECT”, “OPERATOR OVERRIDE”
Front panel controls
"CONNECT”, “DISCONNECT”, “OPERATOR OVERRIDE”
Rear panel control
Monitor volume control
Input power
+11 to +15 VDC (12VDC nominal)
Input current
80mA @ +12.6 V input
Size
185mm W x 270mm D x 70mm H
(2000 series standard enclosure)
Weight
0.8kg
Environmental
Operating temperature
-20°C to +55°C
Storage temperature
-40°C to +85°C
Humidity
Up to 95% @ 55°C
Shock
MIL-STD-810D, method 516.3 procedure VI
Vibration
MIL-STD-810D, method 514.3 Category
Summary of Contents for 2061