background image

Barracuda Web Security Gateway

Step 2 - Installation

3 / 5

In a browser on the connected computer, log in to the default web interface

2.

http://192.168.200.200:8000. Use admin for the username and, for the password: 

- If your appliance serial number is higher then 1

311431

, then the default administrator

password is the numeric portion of the serial number. For help finding the serial number
of your appliance, see 

Serial Number for Hardware and Virtual Appliances.

- If your serial number is 1311431 or lower, then the default administrator password is
admin.

Go to the BASIC > IP Configuration page. In the TCP/IP Configuration section, enter

3.

the new IP Address, Subnet Mask and Default Gateway. Choose an IP address that is
on the same subnet as the devices that will be connected to the WAN and LAN ports of
the Barracuda Web Security Gateway when it is deployed. The Default Gateway is the IP
address of the next outbound hop from the Barracuda Web Security Gateway. The
Barracuda Web Security Gateway sends all egress traffic to the default gateway via the
WAN port on the front (or back, depending on the model) of the appliance.
In the DNS Configuration section, enter the Primary DNS and Secondary DNS server

4.

IP addresses. These fields are required to resolve to Barracuda support servers upon
initial setup to activate the appliance and receive software updates.
In the Domain Configuration section, set the Default Host Name and Default

5.

Domain.
Click Save, and then reboot the Barracuda Web Security Gateway.

6.

To set a new IP address from the administrative console:

With your keyboard and monitor connected directly to the Barracuda Web Security Gateway, at

1.

the barracuda login prompt, enter admin for the login and, for the password:

- If your appliance serial number is higher then 1

311431

 , then the default administrator

password is the numeric portion of the serial number. For help finding the serial number of your
appliance, see 

Serial Number for Hardware and Virtual Appliances.

- If your serial number is 1311431 or lower, then the default administrator password is admin.

Using the arrow keys, select TCP/IP Configuration from the menu and then Tab over to the

2.

TCP/IP Configuration submenu.
Enter the new IP Address and Subnet Mask for your Barracuda Web Security Gateway. For

3.

proper Default Gateway setup, note that the Default Gateway is the IP address of the next
outbound hop from the Barracuda Web Security Gateway, which sends all egress traffic to this
gateway via the WAN port. For Forward Proxy deployment, use the same Default Gateway that
is used by hosts on the network. Your firewall must be on the same subnet as the Barracuda
Web Security Gateway.
The Primary DNS and Secondary DNS fields are required to resolve to Barracuda support

4.

servers upon initial setup to activate the appliance and receive software updates.
Select Save to enter your changes.

5.

Select Exit.

6.

The new IP address and network settings are applied to your Barracuda Web Security Gateway.