ROHS compliant

Yes

Power & Efficiency

Power supply

Dual, with two external PSU adapters

Power supply type

External

External power supply is not included in delivery of the appliance and needs to be ordered
individually.

Power connector

Phoenix contact
6-pin connector w/ lock

Power type [AC/DC]

DC

Input rating [Volts]

12 - 36

Wattage / max. power draw [W]

60

Max. power draw (@ 24Vdc) [A]

2

Max. heat dissipation [W]

60

IP Code

• IP30 - With a 6-pin phoenix connector used.
• IP20 - With a 2-pin phoenix connector used.

The hardware specifications list was valid at the time this manual was published. The listed
components are subject to change at any time, as Barracuda Networks may change hardware
components due to technological advancements. Therefore, the list may not reflect the current
hardware configuration of the Barracuda appliance it was delivered with.

Dual Power Supply Connector and P-Fail relay (6-PIN connector)

F183R appliances are equipped with a 6-pin connector, for connecting two external power supplies
and an alarm device in case of failure. The appliance can run with one or two external power supplies.

As F183R comes with dual power and P-fail relay features, the P-Fail relay will have the signaling
device triggered as the power supply fails. The relay circuit is set to be open by default and closed
when either or neither of the powers is detected; the closed (or short) circuit then allows the alarm
device to be activated. Please note that the alarm device needs its own power circuit.

PWR1

PWR2

Circuit Status Alarm Device

Detected

Detected

Open (Normal)

Off

Not Detected

Detected

Closed

Activated

Detected

Not Detected

Closed

Activated

Not Detected Not Detected

Closed

Activated

Summary of Contents for CloudGen F183R

Page 1: ...ce Safety Instructions Power supply is not included in packaging and needs to be ordered separately BNGPSUR1a BNGIPSUR1a To prevent damage connect the DC plug to the appliance before plugging the powe...

Page 2: ...a Storage RAM GB 4 or higher Mass Storage Type SSD Size GB 100 Size Weight Dimensions Appliance weight kg 1 0 Carton weight with appliance kg N A Appliance size width x depth x height mm 78 x 127x 146...

Page 3: ...Therefore the list may not re ect the current hardware con guration of the Barracuda appliance it was delivered with Dual Power Supply Connector and P Fail relay 6 PIN connector F183R appliances are...

Page 4: ...the appliance s operational state by changing colors between green and red and by changing between blinking and steady glowing The tables below show the di erent meanings of the di erent glowing stat...

Page 5: ...halted and may be disconnected or an error occurred preventing the appliance from entering the up state Disc LED YELLOW Blinking Appliance is reading or writing on storage Appliance is accessing the i...

Page 6: ...In order to establish a console connection to the appliance using an RS232 serial cable you need to con gure the serial port on the terminal using the following parameters Parameter Value Baud 19200...

Page 7: ...c No portion of this document may be copied distributed publicized or used for other than internal documentary purposes without the written consent of an o cial representative of Barracuda Networks In...

Reviews: