Power supply cord should be routed so that the are not likely to be walked upon or pinched by the items placed on or
against them. When removing the cord from a power outlet be sure to remove it by holding the plug attachment and
not by pulling on the cord.
Check the total maximum power of your AC wall outlet and make sure it has the enough power to match the Power
Consumption of this appliance, otherwise you could overload the wall outlet, which could cause fire.

8. Internal / External Voltage Selectors

Internal of external voltage selector switches, if any, should only be reset

and re-equipped with a proper plug for alternative voltage by a qualified service technician . Do not attempt to alter
this yourself.

9. Object & Liquid Entry

Take care to avoid any objects falling into or liquids are not spilled in to the inside of the

appliance.

10. Cleaning

Unplug the appliance first and clean only with a dry cloth.

11. Non-use Period

The power cord of the appliance should be unplugged from the outlet when left unused for long

periods of time.

12. Unpacking & Setup

Please check your appliance for any damage after unpacking(before connecting) and

contact your dealer in case of any related complains. Take care of choosing your installation place and the correct AC
connection. If built in to a case, be aware that the depth and the weight of some kind appliance(suCH 1s Amplifier)
does require an additional fixing on the backside or the use of rack shelf supports. Never mount the amplifier in a rack
just by fixing it on the front plate – Manufacturer takes no responsibility in this case.

13. Damage Requiring Service

Servicing is required when the appliance has been damaged in any way, suCH 1s

power cord or plug is damaged, liquid has been spilled or objects have fallen in the appliance, the appliance has
been exposed to rain or moisture, does not operate normally, or has been dropped. Refer all servicing to qualified
service personnel or contact your dealer. Do not attempt to repair by yourself.

Front panel:

1. Mains Power Switch

When press the switch, the soft start circuit run for
avoiding surge strike. In about 3-4 seconds, there will be a
clicking denote that soft start finished. And more 1-2
seconds later, there will be another “clicking”, the amplifier
is connected with speaker and ready to work.

2. CH-1/CH-2 Input level control

Adjust it to get the volume desired. Use CH-1 control only
while amplifier is set in Bridge or Parallel mode.

3. Signal LED

The green signal led indicates that a music signal

is present at this channel input.
4.

CH-1/CH-2 Protection indicating LED

This red LED will light up when the amplifier is running
un-stable or went in to thermal protection after the power
elements temperature over 90

.

5. Clip LED

Turns on just before the maximum, distortion free, output
level of the amplifier. The clip leds may turn on shortly
from time to time but they may certainly not turn on for
longer periods. In this case you have to turn the output
level down!

Summary of Contents for T2600

Page 1: ...T2600 PROFESSIONAL POWER AMPLIFIER T2600 PROFESSIONAL POWER AMPLIFIER OWNER S MANUAL OWNER S MANUAL Version 1 0 T2600 T2600...

Page 2: ...nnected and used 2 Retain Instructions The safety and operating instructions should be kept for future reference 3 Heed Waning All warnings on this appliance and in these operating instructions should...

Page 3: ...uire an additional fixing on the backside or the use of rack shelf supports Never mount the amplifier in a rack just by fixing it on the front plate Manufacturer takes no responsibility in this case 1...

Page 4: ...ard binding connector 4 OUTPUT MODE SET SWITCH BRIDGE MONO MODE Sends CH 1 signals out of phase to CH 2 producing twice the normal voltage swing between the two RED speaker terminals CH 1 RED is defin...

Page 5: ...0kHz 0 5dB Input Sensitivity 0 77V 1 4V 26dB Input Impedance 20k Balanced 10k un Balanced S N Ratio 95dB THD 0 03 Crosstalk Rated Output 8 1kHz 70 dB Damping Factor 8 1kHz 240 Slew Rate 15V uS Protect...

Page 6: ...5 1 2 3 4 5 6 7 8 9 10 11 12 13...

Page 7: ...2 2 CH 1 CH 2 3 CH 1 CH 2 4 CH 1 CH 2 1 3 5 2 90 C 5 6 CH 1 7 CH1 8 1 2 SPEAKON SPEAKON 1 1 3 CH 1 CH 2 4 CH 1 180 CH 2 CH 1 CH 1 CH 1 CH 2 CH 1 5 26dB 1 4V 0 77V 6 CH 1 CH 2 XLR XLR XLR 1 2 3 7 CH 1...

Page 8: ...ON and Binding 20Hz 20kHz 0 5dB 0 77V 1 4V 26dB 20k Balanced 10k un Balanced 95dB 0 03 8 ohm 1KHz 70 dB f 1KHz 8 OHMS 240 15V uS Soft Start Short Circuit Limiter DC Fault AC Line Fuse Thermal Cut Two...

Reviews: