Barnes BP25VF Installation Manual Download Page 3

3

DISCHARGE .......................

1½” NPT, Female, Vertical

LIQUID TEMPERATURE ....

77°F (25°C) Continuous

MOTOR HOUSING .............

Cast Iron

BODY & STRAINER ...........

Thermoplastic

IMPELLER:

 

Design

 ............

Multi-Vane

 

Material

 ...........

Thermoplastic

SHAFT .................................

Carbon Steel

SQUARE RINGS .................

Buna-N

HARDWARE .......................

300 Series Stainless Steel

PAINT ..................................

Air dry enamel

SEAL

 

Design

 .............

Single Mechanical, Oil Filled

 

Material

 ...........

Carbon/Ceramic/Buna-N

 

Hardware - 300 series stainless steel

CORD ENTRY .....................

10 Ft. (3m) Cord with  Plug and

  

pressure gromment for sealing and 

 strain 

relief.

LOWER BEARING:

 

Design

 .............

Sleeve

MOTOR:

 

Design

 .............

Oil Filled

 

Insulation

 ........

Class B

SINGLE PHASE ..................

Shaded Pole Includes Overload

 Protection 

in 

Motor

LEVEL CONTROLS:

 

BP25A ............. Wide Angle, Mechanical, 10 Ft. (3m)

 Cord 
 

BP25VF .......... Vertical Float, PVC, Snap Action,

 

10 Ft. (3m) cord 

MINIMUM SUMP DIA:

 BP25A 

............. 18” 

(457mm)

 BP25VF 

.......... 11” 

(279mm)

 

SECTION: A - PUMP SPECIFICATIONS

inches

(mm)

Model: BP25VF

Model: BP25A

IMPORTANT !

1.)  PUMP MAY BE OPERATED “DRY” FOR EXTENDED PERIODS WITHOUT DAMAGE TO MOTOR AND/OR SEALS. 
2.)  THIS PUMP IS APPROPRIATE FOR THOSE APPLICATIONS SPECIFIED AS CLASS I DIVISION II HAZARDOUS LOCATIONS. 
3.)  THIS PUMP IS NOT APPROPRIATE FOR THOSE APPLICATIONS SPECIFIED AS CLASS I DIVISION I HAZARDOUS LOCATIONS.
4.)  INSTALLATIONS SUCH AS DECORATIVE FOUNTAINS OR WATER FEATURES PROVIDED FOR VISUAL ENJOYMENT MUST BE INSTALLED
 

IN ACCORDANCE WITH THE NATIONAL ELECTRIC CODE ANSI/NFPA 70 AND/OR THE AUTHORITY HAVING JURISDICTION. THIS PUMP IS

 

NOT INTENDED FOR USE IN SWIMMING POOLS, RECREATIONAL WATER PARKS, OR INSTALLATIONS IN WHICH HUMAN CONTACT 

 

WITH PUMPED MEDIA IS A COMMON OCCURRENCE.

Summary of Contents for BP25VF

Page 1: ...program product changes may occur As such Crane Pumps Systems reserves the right to change product without prior written noti cation 420 Third Street 83 West Drive Bramton Piqua Ohio 45356 Ontario Can...

Page 2: ...n pumps Make sure lifting handles are securely fastened each time before lifting DO NOT operate pump without safety devices in place Always replace safety devices that have been removed during service...

Page 3: ...t 3m Cord BP25VF Vertical Float PVC Snap Action 10 Ft 3m cord MINIMUM SUMP DIA BP25A 18 457mm BP25VF 11 279mm SECTION A PUMP SPECIFICATIONS inches mm Model BP25VF Model BP25A IMPORTANT 1 PUMP MAY BE O...

Page 4: ...arnes representative or Crane Pumps Systems Inc Service Department in Piqua Ohio telephone 937 778 8947 or Crane Pumps Systems Canada Inc Bramton Ontario 905 457 6223 SECTION C INSTALLATION C 1 Locati...

Page 5: ...t the pump up after the motor cools to a safe temperature In the event of an overload the source of this condition should be determined and recti ed immediately DO NOT LET THE PUMP CYCLE OR RUN IF AN...

Page 6: ...information E 2 Model Number This designation consists of numbers and letters which represents the horsepower motor phase and voltage and pump design This number is used for ordering and obtain ing in...

Page 7: ...7 60 Hz Testing is performed with water speci c gravity of 1 0 68 F other uids may vary performance...

Page 8: ...8 Notes...

Page 9: ...Check cutter for freedom of operation security and condition Clean cutter and inlet of any obstruction 9 Loosen union slightly to allow trapped air to escape Verify that turn off level of switch is se...

Page 10: ...RESULTING FROM SYSTEMS ANALYSES AND EVALUATIONS WE CONDUCT WILL BE BASED ON OUR BEST AVAILABLE EXPERIENCE AND PUBLISHED INDUSTRY INFORMATION SUCH RECOMMENDATIONS DO NOT CONSTITUTE A WARRANTY OF SATIS...

Page 11: ...CITY STATE ZIP MODEL NO SERIAL NO PART NO BRAND IMPORTANT WARRANTY REGISTRATION Your product is covered by the enclosed Warranty Complete the Warranty Registration Form and return to Crane Pumps Syst...

Page 12: ...CRANE PUMPS SYSTEMS INC WARRANTY SERVICE GROUP 420 THIRD STREET PIQUA OHIO 45356 U S A FOLD HERE AND TAPE DO NOT STAPLE PLACE STAMP HERE...

Reviews: