18 |
Set up BRNKL
Add house battery
D | Prepare BRNKL wiring
At the BRNKL end of the wiring:
1. Trim any extra wire.
2. Strip 5 mm (1/4”) of insulation
from the ends of the
red wire
and
black wire
.
5 mm
C | Prepare common ground
wiring
At the common ground end of wiring:
1. Trim any extra wire.
2. Strip 10 mm (1/2”) of insulation
from the end of the wire.
3. Connect and crimp a ring terminal
to the wire.
Size the ring terminal to fit the
common ground terminal.
Heat seal the connection.
10 mm