DISCHARGE: 

   

SPHERICAL SLD HNDLG: 
LIQUID TEMPERATURE:

  

VOLUTE:

  

MOTOR HOUSING:

    

SEAL PLATE:

    

IMPELLER:

 

 

SHAFT: 

 

SQUARE RINGS:

 

PAINT:

  

SEAL:   

DIAPHRAGM:

 

HARDWARE:

 

CORD ENTRY: 

UPPER BEARING:

 

LOWER BEARING:

 

MOTOR:

 

4", 125lb, flange horizontal.
3"
104° F (40° C) max.
Cast iron ASTM A-48 class 30.
Cast iron ASTM A-48 class 30.
Cast iron ASTM A-48 class 30.
2 vane, closed, with vanes on back side. Cast iron ASTM A-48 class 30.
416 series stainless steel.
Buna-N.
Air dry enamel, water based.
Double mechanical, oil filled chamber. Silicon carbide outboard, carbon 
ceramic inboard seal, Buna-N elastomer and stainless steel hardware.
Buna-N.
300 series stainless steel.
40 ft of cord, epoxy sealed housing with secondary pressure grommet for sealing 
and strain relief.
Ball, single row, oil lubricated, for radial load.
Ball, single row, oil lubricated, for radial and thrust load.
Three  phase,  NEMA  B,  oil  filled.  Requires  overload  protection  to  be  included  in 

control panel. Class F insulation.

MOISTURE SENSOR:

   

Normally open (N/O) included, requires relay in control panel.

TEMPERATURE SENSOR

Normally closed (N/C) included, requires relay in control panel.

OPTIONAL EQUIPMENT:

 

Additional cord, tungsten carbide seal, slide rail coupling (SRC-4).

The moisture cord and/or temperature cord is size 18/5, type SO, Ø0.485", for all models.

MODEL

HP VOLTS PHASE

RPM

(Nominal)

MAX

AMPS

LOCKED

ROTOR AMPS

NEMA

CODE

CORD

SIZE

CORD

TYPE

CORD

O. D.

WEIGHT

(pounds)

4BSE753HLDS

7.5

230

3

1750

26.8

80

D

10/4

SO

0.75"

309

4BSE754HLDS

7.5

460

3

1750

13.4

40

D

10/4

SO

0.75"

309

4BSE1133HLDS 11.3

230

3

1750

28

126

D

10/4

SO

0.75"

340

4BSE1134HLDS 11.3

460

3

1750

14

63

D

10/4

SO

0.75"

340

4BSE1503HLDS 15

230

3

1750

38

160

D

10/4

SO

0.75"

400

4BSE1504HLDS 15

460

3

1750

19

80

D

10/4

SO

0.75"

400

02

Specifications & Dimensions

barmesapumps.com

19"

19"

14.5"

14.5"

11.75"

11.75"

7.88"

7.88"

5.5"

5.5"

34.12"

34.12"

Summary of Contents for 4BSE-HLDS Series

Page 1: ...llation Operation Maintenance Manual Submersible Solids Handling Pumps 4BSE HLDS 7 5 11 3 15 HP 1750 RPM IMPORTANT Read all instructions in this manual before operating or servicing a pump barmesapump...

Page 2: ...ry items associatedwithornearthepump T h i s p u m p i s n o t i n t e n d e d f o r u s e i n swimming pools or water installations where there is DANGER humancontactwithpumpedfluid Riskofelectric sh...

Page 3: ...EMA B oil filled Requires overload protection to be included in controlpanel ClassFinsulation MOISTURESENSOR Normallyopen N O included requiresrelayincontrolpanel TEMPERATURESENSOR Normallyclosed N C...

Page 4: ...asin to accommodate the additional backflow volume Pumps are most commonly installed in simplex or duplex stations or basins with a slide rail system Barmesa SRC which allows the pump s to be installe...

Page 5: ...wer and observe the kickback Kickback should always be in a counter clockwise direction as viewed from motor end or opposite to impeller rotation Impeller rotation is counter clockwise as viewed from...

Page 6: ...in the top of the housing to compensate for oil expansion Reassemble the o ring 5 and conduit box 4 to motor housing 3 Apply thread locking compound to cap screws 6 and place into holes and torque to...

Page 7: ...Remove upper bearing 2 with a wheel puller if damaged or worn Vertically lift stator 1 from rotor shaft Inspect windings for shorts and resistance Test the temperature sensors by checking for continui...

Page 8: ...rd stationary member and align holes for cap screws 25 Conduit Box Assembly Check power 35 and control cables 36 for crackes or damage and replace complete conduit box 4 if required See Figure 4 Bring...

Page 9: ...Clearance between the impeller and volute should be approximately 0 012 inch 08 Service G T1 T7 T2 T8 T3 T9 T4 T5 T6 G L1 L2 L3 GREEN BLACK RED WHITE MOTOR LEADS THREE PHASE 230V AC Cable Motor Lead...

Page 10: ...Figure 6 09 Repair Parts barmesapumps com For Repair Part Please supply Model Number and Serial as shown on Name Plate and Part Description and Part Number as shown on Parts List...

Page 11: ...esapumps com For Repair Part Please supply Model Number and Serial as shown on Name Plate and Part Description and Part Number as shown on Parts List 40 40 91010433 91010433 91010433 03140078C 0314007...

Page 12: ...supply leads to ensure proper impeller rotation 11 Repair fixturesasrequiredtoeliminateleakage 12 Check pump temperature limits and fluid temperature 13 Replace portion of discharge pipe with flexible...

Page 13: ......

Page 14: ......

Reviews: