![BARIX IPAM 400 Preliminary Development Specification Download Page 12](http://html.mh-extra.com/html/barix/ipam-400/ipam-400_preliminary-development-specification_475041012.webp)
Preliminary Development
–
BARIX IP AUDIO MODULE 400
–
V 02.20
–
9.April.2018
Layout Guidelines
12
•
Although all audio inputs are DC-decoupled consider the use of current
limiting resistors in the audio signal path close to the devices connectors. It
is a good procedure to also limit the max input voltage to 3.3 volts using
zener diodes (ZDi) right after the resistor.
•
Carrier PCB Power
and Signal
Domains
Relevant excerpt from previous chapter “General Rules”:
•
All available ground pins of the Barix Audio Module should be attached
to their respective ground domain.
•
You MUST provide analog ground to the PCB and that ground must be
connected to the power supply ground externally to the IPAM (on the
carrier PCB)
•
Avoid signal trace routing crossing domain borders (see graphic above).